EQQ LiteRex

Download product group datasheet

Installation cable for fixed installations indoors and outdoors. Not to be laid in soil nor directly in cast concrete. Can be embedded to the groove filled with plaster. UV-protected oversheath and core insulation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.

Standards SS 424 02 19-5
Reaction to fire Dca-s2,d2,a2
CPR - DoP 2021017_DOP.pdf
Product Environmental Profile (PEP) PEP NXNS-00336-V01.01-EN.pdf
Conductor Circular solid copper, EN/IEC 60228 class 1
Insulation UV-protected polyethylene compound
Core Identification (all color combinations in the cable family) Blue, brown
Yellow-green, blue, brown
Yellow-green, blue, brown, black
Yellow-green, blue, brown, black, grey
Yellow-green, white cores , with black numbers
Oversheath UV-protected polyolefin compound
Colour of the oversheath White

2x1,5 N

Electric number Size Packaging Voltage

2x1,5 N

Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 73
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 2
Min. bending radius
During handling and installation, cable mm 76
In final installation, cable mm 23
During handling and installation, cable cm 8
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.15
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224175
Reka code 1254728
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 73
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 2
Min. bending radius
During handling and installation, cable mm 76
In final installation, cable mm 23
During handling and installation, cable cm 8
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.15
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224168
Reka code 1254728
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 73
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 2
Min. bending radius
During handling and installation, cable mm 76
In final installation, cable mm 23
During handling and installation, cable cm 8
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.15
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224182
Reka code 1254728
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 73
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 2
Min. bending radius
During handling and installation, cable mm 76
In final installation, cable mm 23
During handling and installation, cable cm 8
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.15
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224199
Reka code 1254728

3G1,5

Electric number Size Packaging Voltage

3G1,5

Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 93
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 81
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223956
Reka code 1254730
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 93
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 81
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304457
Reka code 1254730
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 93
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 81
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223932
Reka code 1254730
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 93
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 81
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223925
Reka code 1254730
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 93
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 81
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223949
Reka code 1254730

4G1,5

Electric number Size Packaging Voltage

4G1,5

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 113
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 4
Min. bending radius
During handling and installation, cable mm 87
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.3
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223994
Reka code 1254731
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 113
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 4
Min. bending radius
During handling and installation, cable mm 87
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.3
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223963
Reka code 1254731
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 113
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 4
Min. bending radius
During handling and installation, cable mm 87
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.3
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304082
Reka code 1254731
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 113
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 4
Min. bending radius
During handling and installation, cable mm 87
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.3
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223970
Reka code 1254731
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 113
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 4
Min. bending radius
During handling and installation, cable mm 87
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.3
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176223987
Reka code 1254731

5G1,5

Electric number Size Packaging Voltage

5G1,5

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 135
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 95
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224021
Reka code 1254732
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 135
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 95
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304471
Reka code 1254732
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 135
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 95
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224014
Reka code 1254732
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 135
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 95
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304099
Reka code 1254732
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 135
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 95
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224007
Reka code 1254732
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 135
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 95
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224151
Reka code 1254732

2x2,5 N

Electric number Size Packaging Voltage

2x2,5 N

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 100
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 2
Min. bending radius
During handling and installation, cable mm 88
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.25
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224236
Reka code 1254729
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 100
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 2
Min. bending radius
During handling and installation, cable mm 88
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.25
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224212
Reka code 1254729
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 100
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 2
Min. bending radius
During handling and installation, cable mm 88
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.25
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304112
Reka code 1254729
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 100
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 2
Min. bending radius
During handling and installation, cable mm 88
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.25
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224205
Reka code 1254729
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 100
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 2
Min. bending radius
During handling and installation, cable mm 88
In final installation, cable mm 26
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.25
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224229
Reka code 1254729

3G2,5

Electric number Size Packaging Voltage

3G2,5

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 130
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 93
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224052
Reka code 1254733
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 130
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 93
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304495
Reka code 1254733
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 130
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 93
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224120
Reka code 1254733
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 130
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 93
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224038
Reka code 1254733
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 130
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 93
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224045
Reka code 1254733

4G2,5

Electric number Size Packaging Voltage

4G2,5

Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 161
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 4
Min. bending radius
During handling and installation, cable mm 101
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.5
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224137
Reka code 1254734
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 161
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 4
Min. bending radius
During handling and installation, cable mm 101
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.5
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224113
Reka code 1254734
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 161
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 4
Min. bending radius
During handling and installation, cable mm 101
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.5
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224090
Reka code 1254734
Nominal diameter of complete cable mm 10
Nominal weight of cable kg/km 161
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 4
Min. bending radius
During handling and installation, cable mm 101
In final installation, cable mm 30
During handling and installation, cable cm 10
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.5
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224106
Reka code 1254734

5G2,5

Electric number Size Packaging Voltage

5G2,5

Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 194
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.63
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224144
Reka code 1254735
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 194
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.63
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304518
Reka code 1254735
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 194
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.63
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224083
Reka code 1254735
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 194
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.63
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224069
Reka code 1254735
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 194
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.63
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176304129
Reka code 1254735
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 194
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.63
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176224076
Reka code 1254735