EQQ LiteRex BK

Download product group datasheet

Installation cable for fixed installations indoors and outdoors. Not to be laid in soil nor directly in cast concrete. Can be embedded to the groove filled with plaster. UV-protected oversheath and core insulation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.

Standards SS 424 02 19-5
Reaction to fire Dca-s2,d2,a2
CPR - DoP 2021017_DOP.pdf
Product Environmental Profile (PEP) PEP NXNS-00336-V01.01-EN.pdf
Conductor Circular solid copper, EN/IEC 60228 class 1
Insulation UV-protected polyethylene compound
Core Identification (all color combinations in the cable family) Yellow-green, blue, brown
Yellow-green, blue, brown, black, grey
Oversheath UV-protected polyolefin compound
Colour of the oversheath Black

3G1,5

Electric number Size Packaging Voltage

3G1,5

Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 93
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 81
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176227701
Reka code 1254900
Nominal diameter of complete cable mm 8
Nominal weight of cable kg/km 93
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 3
Min. bending radius
During handling and installation, cable mm 81
In final installation, cable mm 24
During handling and installation, cable cm 8
In final installation, cable cm 2
Max. pulling force
Pulling-eye kN 0.23
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176227787
Reka code 1254900

5G1,5

Electric number Size Packaging Voltage

5G1,5

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 135
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 95
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176227718
Reka code 1254902
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 135
Conductor material Copper
Nominal diameter of conductor mm 1.36
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.5
Number of wires 5
Min. bending radius
During handling and installation, cable mm 95
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 12,1
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176227800
Reka code 1254902

3G2,5

Electric number Size Packaging Voltage

3G2,5

Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 130
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 93
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176227725
Reka code 1254903
Nominal diameter of complete cable mm 9
Nominal weight of cable kg/km 130
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 3
Min. bending radius
During handling and installation, cable mm 93
In final installation, cable mm 28
During handling and installation, cable cm 9
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.38
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176227824
Reka code 1254903

5G2,5

Electric number Size Packaging Voltage

5G2,5

Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 194
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.63
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176227732
Reka code 1254905
Nominal diameter of complete cable mm 11
Nominal weight of cable kg/km 194
Conductor material Copper
Nominal diameter of conductor mm 1.74
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.6
Number of wires 5
Min. bending radius
During handling and installation, cable mm 110
In final installation, cable mm 33
During handling and installation, cable cm 11
In final installation, cable cm 3
Max. pulling force
Pulling-eye kN 0.63
Resistance 20 °C Ω/km 7,41
Minimum cable temperature during transport °C -40
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -40
Maximum conductor temperature in normal operation °C 70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 160
EAN code 6438176227848
Reka code 1254905