FRHF-EMC / BFSI-EMC

Download product group datasheet

Fire-resistant EMC power cable for fixed installations indoors and outdoors. May be buried directly in soil. EMC shielded cable gives an excellent protection against electromagnetic disturbancies. For locations where safety requires the operation of alarm, control, signalling and energy circuits also during a fire. The conductor insulation must be protected against UV-radiation. Installations must be in accordance with national regulations and rules of installations. No requirement for CPR-classification.

Standards SFS 5547, HD 604 5 D
Conductor 1,5-6 mm² circular solid copper, EN/IEC 60228 class 1
10-25 mm² circular stranded copper, EN/IEC 60228 class 2
35-240 mm² sector shaped stranded copper, EN/IEC 60228 class 2
Insulation Cross-linked polyethylene XLPE and mica-tape
Core Identification (all color combinations in the cable family) Blue, brown
Brown, black, grey
Blue, brown, black, grey
Inner covering Extruded filling compound
Metal screen EMC-copper foil and copper wires
Oversheath UV-protected polyolefin compound
Colour of the oversheath Orange

2x1,5/1,5

Electric number Size Packaging Voltage

2x1,5/1,5

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 205
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 15
In final installation, cable cm 10
During handling and installation, cable m 0.15
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.05
Pulling-stocking kN 0.06
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009338
Reka code 1146620

2x2,5/2,5

Electric number Size Packaging Voltage

2x2,5/2,5

Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 251
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 16
In final installation, cable cm 11
During handling and installation, cable m 0.15
In final installation, cable m 0.11
Max. pulling force
Pulling-eye kN 0.08
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009352
Reka code 1146621

2x4/4

Electric number Size Packaging Voltage

2x4/4

Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 340
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.12
Pulling-stocking kN 0.16
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009376
Reka code 1146622

2x6/6

Electric number Size Packaging Voltage

2x6/6

Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 444
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 19
In final installation, cable cm 13
During handling and installation, cable m 0.19
In final installation, cable m 0.13
Max. pulling force
Pulling-eye kN 0.18
Pulling-stocking kN 0.24
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009383
Reka code 1146623

2x10/10

Electric number Size Packaging Voltage

2x10/10

Nominal diameter of complete cable mm 19
Nominal weight of cable kg/km 636
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 23
In final installation, cable cm 16
During handling and installation, cable m 0.23
In final installation, cable m 0.16
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0.4
Resistance 20 °C Ω/km 1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,83
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009390
Reka code 1146624

2x16/16

Electric number Size Packaging Voltage

2x16/16

Nominal diameter of complete cable mm 21
Nominal weight of cable kg/km 877
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 26
In final installation, cable cm 18
During handling and installation, cable m 0.26
In final installation, cable m 0.18
Max. pulling force
Pulling-eye kN 0.48
Pulling-stocking kN 0.64
Resistance 20 °C Ω/km 1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009406
Reka code 1146625

3x1,5/1,5

Electric number Size Packaging Voltage

3x1,5/1,5

Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 229
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 15
In final installation, cable cm 11
During handling and installation, cable m 0.15
In final installation, cable m 0.11
Max. pulling force
Pulling-eye kN 0.07
Pulling-stocking kN 0.09
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009413
Reka code 1146630

3x2,5/2,5

Electric number Size Packaging Voltage

3x2,5/2,5

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 283
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 16
In final installation, cable cm 11
During handling and installation, cable m 0.16
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.11
Pulling-stocking kN 0.15
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009437
Reka code 1146631

3x4/4

Electric number Size Packaging Voltage

3x4/4

Nominal diameter of complete cable mm 16
Nominal weight of cable kg/km 395
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 19
In final installation, cable cm 13
During handling and installation, cable m 0.19
In final installation, cable m 0.13
Max. pulling force
Pulling-eye kN 0.18
Pulling-stocking kN 0.24
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009451
Reka code 1146632

3x6/6

Electric number Size Packaging Voltage

3x6/6

Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 501
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 20
In final installation, cable cm 14
During handling and installation, cable m 0.2
In final installation, cable m 0.14
Max. pulling force
Pulling-eye kN 0.27
Pulling-stocking kN 0.36
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009468
Reka code 1146633

3x10/10

Electric number Size Packaging Voltage

3x10/10

Nominal diameter of complete cable mm 20
Nominal weight of cable kg/km 720
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 24
In final installation, cable cm 16
During handling and installation, cable m 0.24
In final installation, cable m 0.17
Max. pulling force
Pulling-eye kN 0.45
Pulling-stocking kN 0.6
Resistance 20 °C Ω/km 1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,83
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009475
Reka code 1146634

3x25/16

Electric number Size Packaging Voltage

3x25/16

Nominal diameter of complete cable mm 26
Nominal weight of cable kg/km 1427
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 0.9
Number of wires 3
Min. bending radius
During handling and installation, cable cm 32
In final installation, cable cm 22
During handling and installation, cable m 0.32
In final installation, cable m 0.22
Max. pulling force
Pulling-eye kN 1.13
Pulling-stocking kN 1.5
Resistance 20 °C Ω/km 0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009499
Reka code 1146636

3x35/16

Electric number Size Packaging Voltage

3x35/16

Nominal diameter of complete cable mm 26
Nominal weight of cable kg/km 1534
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 0.9
Number of wires 3
Min. bending radius
During handling and installation, cable cm 31
In final installation, cable cm 22
During handling and installation, cable m 0.32
In final installation, cable m 0.22
Max. pulling force
Pulling-eye kN 1.58
Pulling-stocking kN 2.1
Resistance 20 °C Ω/km 0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009505
Reka code 1146637

3x50/25

Electric number Size Packaging Voltage

3x50/25

Nominal diameter of complete cable mm 30
Nominal weight of cable kg/km 2149
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1
Number of wires 3
Min. bending radius
During handling and installation, cable cm 36
In final installation, cable cm 25
During handling and installation, cable m 0.36
In final installation, cable m 0.25
Max. pulling force
Pulling-eye kN 2.25
Pulling-stocking kN 3
Resistance 20 °C Ω/km 0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,727
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009512
Reka code 1146638

3x70/35

Electric number Size Packaging Voltage

3x70/35

Nominal diameter of complete cable mm 34
Nominal weight of cable kg/km 2976
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.1
Number of wires 3
Min. bending radius
During handling and installation, cable cm 41
In final installation, cable cm 28
During handling and installation, cable m 0.41
In final installation, cable m 0.28
Max. pulling force
Pulling-eye kN 3.15
Pulling-stocking kN 4.2
Resistance 20 °C Ω/km 0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,524
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009529
Reka code 1146639

3x95/50

Electric number Size Packaging Voltage

3x95/50

Nominal diameter of complete cable mm 37
Nominal weight of cable kg/km 3732
Conductor material Copper
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 1.1
Number of wires 3
Min. bending radius
During handling and installation, cable cm 45
In final installation, cable cm 31
During handling and installation, cable m 0.45
In final installation, cable m 0.31
Max. pulling force
Pulling-eye kN 4.28
Pulling-stocking kN 5.7
Resistance 20 °C Ω/km 0,193
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,387
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009536
Reka code 1146640

3x120/70

Electric number Size Packaging Voltage

3x120/70

Nominal diameter of complete cable mm 40
Nominal weight of cable kg/km 4734
Conductor material Copper
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 1.2
Number of wires 3
Min. bending radius
During handling and installation, cable cm 48
In final installation, cable cm 34
During handling and installation, cable m 0.48
In final installation, cable m 0.34
Max. pulling force
Pulling-eye kN 5.4
Pulling-stocking kN 7.2
Resistance 20 °C Ω/km 0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,268
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009543
Reka code 1146641

3x185/95

Electric number Size Packaging Voltage

3x185/95

Nominal diameter of complete cable mm 50
Nominal weight of cable kg/km 7244
Conductor material Copper
Nominal cross-sectional area of conductor mm2 185
Nominal thickness of insulation mm 1.6
Number of wires 3
Min. bending radius
During handling and installation, cable cm 60
In final installation, cable cm 42
During handling and installation, cable m 0.6
In final installation, cable m 0.42
Max. pulling force
Pulling-eye kN 8.32
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,0991
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,193
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009567
Reka code 1146643

4x1,5/1,5

Electric number Size Packaging Voltage

4x1,5/1,5

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 284
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.09
Pulling-stocking kN 0.12
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006534012
Reka code 1146660

4x2,5/2,5

Electric number Size Packaging Voltage

4x2,5/2,5

Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 351
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 18
In final installation, cable cm 13
During handling and installation, cable m 0.18
In final installation, cable m 0.13
Max. pulling force
Pulling-eye kN 0.15
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006534029
Reka code 1146661

4x4/4

Electric number Size Packaging Voltage

4x4/4

Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 458
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 20
In final installation, cable cm 14
During handling and installation, cable m 0.2
In final installation, cable m 0.14
Max. pulling force
Pulling-eye kN 0.24
Pulling-stocking kN 0.32
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009628
Reka code 1146662

4x6/6

Electric number Size Packaging Voltage

4x6/6

Nominal diameter of complete cable mm 18
Nominal weight of cable kg/km 586
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 21
In final installation, cable cm 15
During handling and installation, cable m 0.21
In final installation, cable m 0.15
Max. pulling force
Pulling-eye kN 0.36
Pulling-stocking kN 0.48
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006534067
Reka code 1146663

4x10/10

Electric number Size Packaging Voltage

4x10/10

Nominal diameter of complete cable mm 21
Nominal weight of cable kg/km 849
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 25
In final installation, cable cm 18
During handling and installation, cable m 0.25
In final installation, cable m 0.18
Max. pulling force
Pulling-eye kN 0.6
Pulling-stocking kN 0.8
Resistance 20 °C Ω/km 1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,83
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006534104
Reka code 1146664

4x16/16

Electric number Size Packaging Voltage

4x16/16

Nominal diameter of complete cable mm 24
Nominal weight of cable kg/km 1193
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 29
In final installation, cable cm 20
During handling and installation, cable m 0.29
In final installation, cable m 0.2
Max. pulling force
Pulling-eye kN 0.96
Pulling-stocking kN 1.28
Resistance 20 °C Ω/km 1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006022274
Reka code 1146676

4x25/16

Electric number Size Packaging Voltage

4x25/16

Nominal diameter of complete cable mm 29
Nominal weight of cable kg/km 1722
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 0.9
Number of wires 4
Min. bending radius
During handling and installation, cable cm 34
In final installation, cable cm 24
During handling and installation, cable m 0.34
In final installation, cable m 0.24
Max. pulling force
Pulling-eye kN 1.5
Pulling-stocking kN 2
Resistance 20 °C Ω/km 0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006022281
Reka code 1146666

4x35/16

Electric number Size Packaging Voltage

4x35/16

Nominal diameter of complete cable mm 29
Nominal weight of cable kg/km 1940
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 0.9
Number of wires 4
Min. bending radius
During handling and installation, cable cm 34
In final installation, cable cm 24
During handling and installation, cable m 0.34
In final installation, cable m 0.24
Max. pulling force
Pulling-eye kN 2.1
Pulling-stocking kN 2.8
Resistance 20 °C Ω/km 0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006022298
Reka code 1146667
Nominal diameter of complete cable mm 29
Nominal weight of cable kg/km 1940
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 0.9
Number of wires 4
Min. bending radius
During handling and installation, cable cm 34
In final installation, cable cm 24
During handling and installation, cable m 0.34
In final installation, cable m 0.24
Max. pulling force
Pulling-eye kN 2.1
Pulling-stocking kN 2.8
Resistance 20 °C Ω/km 0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006022007
Reka code 1146667

4x50/25

Electric number Size Packaging Voltage

4x50/25

Nominal diameter of complete cable mm 33
Nominal weight of cable kg/km 2623
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1
Number of wires 4
Min. bending radius
During handling and installation, cable cm 40
In final installation, cable cm 28
During handling and installation, cable m 0.4
In final installation, cable m 0.28
Max. pulling force
Pulling-eye kN 3
Pulling-stocking kN 4
Resistance 20 °C Ω/km 0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,727
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006022304
Reka code 1146668

4x70/35

Electric number Size Packaging Voltage

4x70/35

Nominal diameter of complete cable mm 35
Nominal weight of cable kg/km 3533
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.1
Number of wires 4
Min. bending radius
During handling and installation, cable cm 43
In final installation, cable cm 30
During handling and installation, cable m 0.43
In final installation, cable m 0.3
Max. pulling force
Pulling-eye kN 4.2
Pulling-stocking kN 5.6
Resistance 20 °C Ω/km 0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,524
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006022311
Reka code 1146669

4x95/50

Electric number Size Packaging Voltage

4x95/50

Nominal diameter of complete cable mm 41
Nominal weight of cable kg/km 4707
Conductor material Copper
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 1.1
Number of wires 4
Min. bending radius
During handling and installation, cable cm 49
In final installation, cable cm 34
During handling and installation, cable m 0.49
In final installation, cable m 0.34
Max. pulling force
Pulling-eye kN 5.7
Pulling-stocking kN 7.6
Resistance 20 °C Ω/km 0,193
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,387
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006022328
Reka code 1146670

4x120/70

Electric number Size Packaging Voltage

4x120/70

Nominal diameter of complete cable mm 44
Nominal weight of cable kg/km 5893
Conductor material Copper
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 1.2
Number of wires 4
Min. bending radius
During handling and installation, cable cm 54
In final installation, cable cm 38
During handling and installation, cable m 0.54
In final installation, cable m 0.38
Max. pulling force
Pulling-eye kN 7.2
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,268
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006022335
Reka code 1146671

4x150/70

Electric number Size Packaging Voltage

4x150/70

Nominal diameter of complete cable mm 49
Nominal weight of cable kg/km 7117
Conductor material Copper
Nominal cross-sectional area of conductor mm2 150
Nominal thickness of insulation mm 1.4
Number of wires 4
Min. bending radius
During handling and installation, cable cm 58
In final installation, cable cm 41
During handling and installation, cable m 0.58
In final installation, cable m 0.41
Max. pulling force
Pulling-eye kN 9
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,124
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,268
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006022342
Reka code 1146672

4x185/95

Electric number Size Packaging Voltage

4x185/95

Nominal diameter of complete cable mm 57
Nominal weight of cable kg/km 9197
Conductor material Copper
Nominal cross-sectional area of conductor mm2 185
Nominal thickness of insulation mm 1.6
Number of wires 4
Min. bending radius
During handling and installation, cable cm 68
In final installation, cable cm 47
During handling and installation, cable m 0.68
In final installation, cable m 0.47
Max. pulling force
Pulling-eye kN 11.1
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,0991
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,193
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006022359
Reka code 1146673

4x240/120

Electric number Size Packaging Voltage

4x240/120

Nominal diameter of complete cable mm 62
Nominal weight of cable kg/km 11787
Conductor material Copper
Nominal cross-sectional area of conductor mm2 240
Nominal thickness of insulation mm 1.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 74
In final installation, cable cm 52
During handling and installation, cable m 0.74
In final installation, cable m 0.52
Max. pulling force
Pulling-eye kN 14.4
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,0754
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,153
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176009741
Reka code 1146674
Nominal diameter of complete cable mm 62
Nominal weight of cable kg/km 11787
Conductor material Copper
Nominal cross-sectional area of conductor mm2 240
Nominal thickness of insulation mm 1.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 74
In final installation, cable cm 52
During handling and installation, cable m 0.74
In final installation, cable m 0.52
Max. pulling force
Pulling-eye kN 14.4
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,0754
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,153
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6410006022366
Reka code 1146674