MK-HF / H07Z1-R
Download product group datasheet
Installation wirefor fixed installations indoors. For internal wiring of electrical devices. The conductor insulation must be protected against UV-radiation. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.
Standards | EN 50525-3-31 |
---|---|
Reaction to fire | Dca-s2,d2,a2 |
CPR - DoP | 2020005_DOP.pdf 2017043_DOP.pdf |
Conductor | Circular stranded copper, EN/IEC 60228 class 2 |
Insulation | Polyolefine compound |
Core Identification (all color combinations in the cable family) | GNYE Yellow-green, BU Blue BN Brown, BK Black GY Grey, OG Orange RD Red, WH White VT Violet, PK Pink |
1,5 GY H07Z1-R
Electric number
Size
Packaging
Voltage
1,5 GY H07Z1-R
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
22
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
24
In final installation, cable mm
9
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223666
Reka code
1145660
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
22
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
24
In final installation, cable mm
9
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002001
Reka code
1145660
1,5 BN H07Z1-R
Electric number
Size
Packaging
Voltage
1,5 BN H07Z1-R
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
22
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
24
In final installation, cable mm
9
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223635
Reka code
1145662
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
22
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
24
In final installation, cable mm
9
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002025
Reka code
1145662
1,5 BK H07Z1-R
Electric number
Size
Packaging
Voltage
1,5 BK H07Z1-R
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
22
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
24
In final installation, cable mm
9
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223642
Reka code
1145663
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
22
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
24
In final installation, cable mm
9
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002032
Reka code
1145663
1,5 BU H07Z1-R
Electric number
Size
Packaging
Voltage
1,5 BU H07Z1-R
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
22
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
24
In final installation, cable mm
9
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223628
Reka code
1145667
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
22
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
24
In final installation, cable mm
9
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002070
Reka code
1145667
1,5 GNYE H07Z1-R
Electric number
Size
Packaging
Voltage
1,5 GNYE H07Z1-R
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
22
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
24
In final installation, cable mm
9
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223611
Reka code
1145668
Nominal diameter of complete cable mm
3
Nominal weight of cable kg/km
22
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
1
Min. bending radius
During handling and installation, cable mm
24
In final installation, cable mm
9
During handling and installation, cable cm
2
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.08
Pulling-stocking kN
0
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002087
Reka code
1145668
2,5 GY H07Z1-R
Electric number
Size
Packaging
Voltage
2,5 GY H07Z1-R
Nominal diameter of complete cable mm
4
Nominal weight of cable kg/km
34
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
29
In final installation, cable mm
11
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002100
Reka code
1145670
Nominal diameter of complete cable mm
4
Nominal weight of cable kg/km
34
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
29
In final installation, cable mm
11
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223734
Reka code
1145670
2,5 BN H07Z1-R
Electric number
Size
Packaging
Voltage
2,5 BN H07Z1-R
Nominal diameter of complete cable mm
4
Nominal weight of cable kg/km
34
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
29
In final installation, cable mm
11
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002124
Reka code
1145672
Nominal diameter of complete cable mm
4
Nominal weight of cable kg/km
34
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
29
In final installation, cable mm
11
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223703
Reka code
1145672
2,5 BK H07Z1-R
Electric number
Size
Packaging
Voltage
2,5 BK H07Z1-R
Nominal diameter of complete cable mm
4
Nominal weight of cable kg/km
34
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
29
In final installation, cable mm
11
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223710
Reka code
1145673
Nominal diameter of complete cable mm
4
Nominal weight of cable kg/km
34
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
29
In final installation, cable mm
11
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002131
Reka code
1145673
2,5 BU H07Z1-R
Electric number
Size
Packaging
Voltage
2,5 BU H07Z1-R
Nominal diameter of complete cable mm
4
Nominal weight of cable kg/km
34
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
29
In final installation, cable mm
11
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223697
Reka code
1145677
Nominal diameter of complete cable mm
4
Nominal weight of cable kg/km
34
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
29
In final installation, cable mm
11
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002179
Reka code
1145677
2,5 GNYE H07Z1-R
Electric number
Size
Packaging
Voltage
2,5 GNYE H07Z1-R
Nominal diameter of complete cable mm
4
Nominal weight of cable kg/km
34
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
29
In final installation, cable mm
11
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176223680
Reka code
1145678
Nominal diameter of complete cable mm
4
Nominal weight of cable kg/km
34
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
29
In final installation, cable mm
11
During handling and installation, cable cm
3
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.13
Pulling-stocking kN
0
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002186
Reka code
1145678
6 BK H07Z1-R
Electric number
Size
Packaging
Voltage
6 BK H07Z1-R
Nominal diameter of complete cable mm
5
Nominal weight of cable kg/km
71
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
6
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
38
In final installation, cable mm
14
During handling and installation, cable cm
4
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.3
Pulling-stocking kN
0
Resistance 20 °C Ω/km
3,08
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002537
Reka code
1145693
Nominal diameter of complete cable mm
5
Nominal weight of cable kg/km
71
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
6
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
38
In final installation, cable mm
14
During handling and installation, cable cm
4
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.3
Pulling-stocking kN
0
Resistance 20 °C Ω/km
3,08
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004540138
Reka code
1145693
6 GNYE H07Z1-R
Electric number
Size
Packaging
Voltage
6 GNYE H07Z1-R
Nominal diameter of complete cable mm
5
Nominal weight of cable kg/km
71
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
6
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
38
In final installation, cable mm
14
During handling and installation, cable cm
4
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.3
Pulling-stocking kN
0
Resistance 20 °C Ω/km
3,08
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002582
Reka code
1145698
Nominal diameter of complete cable mm
5
Nominal weight of cable kg/km
71
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
6
Nominal thickness of insulation mm
0.8
Number of wires
1
Min. bending radius
During handling and installation, cable mm
38
In final installation, cable mm
14
During handling and installation, cable cm
4
In final installation, cable cm
1
Max. pulling force
Pulling-eye kN
0.3
Pulling-stocking kN
0
Resistance 20 °C Ω/km
3,08
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004540282
Reka code
1145698
10 GNYE H07Z1-R
Electric number
Size
Packaging
Voltage
10 GNYE H07Z1-R
Nominal diameter of complete cable mm
6
Nominal weight of cable kg/km
115
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
1
Number of wires
1
Min. bending radius
During handling and installation, cable mm
48
In final installation, cable mm
18
During handling and installation, cable cm
5
In final installation, cable cm
2
Max. pulling force
Pulling-eye kN
0.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
1,83
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002780
Reka code
1145708
16 BK H07Z1-R
Electric number
Size
Packaging
Voltage
16 BK H07Z1-R
Nominal diameter of complete cable mm
7
Nominal weight of cable kg/km
181
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
1
Number of wires
1
Min. bending radius
During handling and installation, cable mm
58
In final installation, cable mm
22
During handling and installation, cable cm
6
In final installation, cable cm
2
Max. pulling force
Pulling-eye kN
0.8
Pulling-stocking kN
0
Resistance 20 °C Ω/km
1,15
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006528
Reka code
1145713
Nominal diameter of complete cable mm
7
Nominal weight of cable kg/km
181
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
1
Number of wires
1
Min. bending radius
During handling and installation, cable mm
58
In final installation, cable mm
22
During handling and installation, cable cm
6
In final installation, cable cm
2
Max. pulling force
Pulling-eye kN
0.8
Pulling-stocking kN
0
Resistance 20 °C Ω/km
1,15
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002834
Reka code
1145713
Nominal diameter of complete cable mm
7
Nominal weight of cable kg/km
181
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
1
Number of wires
1
Min. bending radius
During handling and installation, cable mm
58
In final installation, cable mm
22
During handling and installation, cable cm
6
In final installation, cable cm
2
Max. pulling force
Pulling-eye kN
0.8
Pulling-stocking kN
0
Resistance 20 °C Ω/km
1,15
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004540237
Reka code
1145713
16 BU H07Z1-R
Electric number
Size
Packaging
Voltage
16 BU H07Z1-R
Nominal diameter of complete cable mm
7
Nominal weight of cable kg/km
181
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
1
Number of wires
1
Min. bending radius
During handling and installation, cable mm
58
In final installation, cable mm
22
During handling and installation, cable cm
6
In final installation, cable cm
2
Max. pulling force
Pulling-eye kN
0.8
Pulling-stocking kN
0
Resistance 20 °C Ω/km
1,15
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006542
Reka code
1145717
Nominal diameter of complete cable mm
7
Nominal weight of cable kg/km
181
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
1
Number of wires
1
Min. bending radius
During handling and installation, cable mm
58
In final installation, cable mm
22
During handling and installation, cable cm
6
In final installation, cable cm
2
Max. pulling force
Pulling-eye kN
0.8
Pulling-stocking kN
0
Resistance 20 °C Ω/km
1,15
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004540275
Reka code
1145717
Nominal diameter of complete cable mm
7
Nominal weight of cable kg/km
181
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
1
Number of wires
1
Min. bending radius
During handling and installation, cable mm
58
In final installation, cable mm
22
During handling and installation, cable cm
6
In final installation, cable cm
2
Max. pulling force
Pulling-eye kN
0.8
Pulling-stocking kN
0
Resistance 20 °C Ω/km
1,15
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002872
Reka code
1145717
16 GNYE H07Z1-R
Electric number
Size
Packaging
Voltage
16 GNYE H07Z1-R
Nominal diameter of complete cable mm
7
Nominal weight of cable kg/km
181
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
1
Number of wires
1
Min. bending radius
During handling and installation, cable mm
58
In final installation, cable mm
22
During handling and installation, cable cm
6
In final installation, cable cm
2
Max. pulling force
Pulling-eye kN
0.8
Pulling-stocking kN
0
Resistance 20 °C Ω/km
1,15
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004540084
Reka code
1145718
Nominal diameter of complete cable mm
7
Nominal weight of cable kg/km
181
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
1
Number of wires
1
Min. bending radius
During handling and installation, cable mm
58
In final installation, cable mm
22
During handling and installation, cable cm
6
In final installation, cable cm
2
Max. pulling force
Pulling-eye kN
0.8
Pulling-stocking kN
0
Resistance 20 °C Ω/km
1,15
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004002889
Reka code
1145718
Nominal diameter of complete cable mm
7
Nominal weight of cable kg/km
181
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
1
Number of wires
1
Min. bending radius
During handling and installation, cable mm
58
In final installation, cable mm
22
During handling and installation, cable cm
6
In final installation, cable cm
2
Max. pulling force
Pulling-eye kN
0.8
Pulling-stocking kN
0
Resistance 20 °C Ω/km
1,15
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004540381
Reka code
1145718
25 BK H07Z1-R
Electric number
Size
Packaging
Voltage
25 BK H07Z1-R
Nominal diameter of complete cable mm
9
Nominal weight of cable kg/km
277
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
70
In final installation, cable mm
26
During handling and installation, cable cm
7
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.25
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,727
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006597
Reka code
1145723
Nominal diameter of complete cable mm
9
Nominal weight of cable kg/km
277
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
70
In final installation, cable mm
26
During handling and installation, cable cm
7
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.25
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,727
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003039
Reka code
1145723
Nominal diameter of complete cable mm
9
Nominal weight of cable kg/km
277
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
70
In final installation, cable mm
26
During handling and installation, cable cm
7
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.25
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,727
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006580
Reka code
1145723
25 BU H07Z1-R
Electric number
Size
Packaging
Voltage
25 BU H07Z1-R
Nominal diameter of complete cable mm
9
Nominal weight of cable kg/km
277
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
70
In final installation, cable mm
26
During handling and installation, cable cm
7
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.25
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,727
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003077
Reka code
1145727
Nominal diameter of complete cable mm
9
Nominal weight of cable kg/km
277
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
70
In final installation, cable mm
26
During handling and installation, cable cm
7
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.25
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,727
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006610
Reka code
1145727
Nominal diameter of complete cable mm
9
Nominal weight of cable kg/km
277
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
70
In final installation, cable mm
26
During handling and installation, cable cm
7
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.25
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,727
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006603
Reka code
1145727
25 GNYE H07Z1-R
Electric number
Size
Packaging
Voltage
25 GNYE H07Z1-R
Nominal diameter of complete cable mm
9
Nominal weight of cable kg/km
277
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
70
In final installation, cable mm
26
During handling and installation, cable cm
7
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.25
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,727
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004540480
Reka code
1145728
Nominal diameter of complete cable mm
9
Nominal weight of cable kg/km
277
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
70
In final installation, cable mm
26
During handling and installation, cable cm
7
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.25
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,727
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003084
Reka code
1145728
Nominal diameter of complete cable mm
9
Nominal weight of cable kg/km
277
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
70
In final installation, cable mm
26
During handling and installation, cable cm
7
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.25
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,727
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006634
Reka code
1145728
35 BK H07Z1-R
Electric number
Size
Packaging
Voltage
35 BK H07Z1-R
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
372
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
80
In final installation, cable mm
30
During handling and installation, cable cm
8
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.75
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,524
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003138
Reka code
1145733
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
372
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
80
In final installation, cable mm
30
During handling and installation, cable cm
8
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.75
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,524
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006641
Reka code
1145733
35 BU H07Z1-R
Electric number
Size
Packaging
Voltage
35 BU H07Z1-R
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
372
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
80
In final installation, cable mm
30
During handling and installation, cable cm
8
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.75
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,524
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006665
Reka code
1145737
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
372
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
80
In final installation, cable mm
30
During handling and installation, cable cm
8
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.75
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,524
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003176
Reka code
1145737
35 GNYE H07Z1-R
Electric number
Size
Packaging
Voltage
35 GNYE H07Z1-R
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
372
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
80
In final installation, cable mm
30
During handling and installation, cable cm
8
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.75
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,524
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003183
Reka code
1145738
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
372
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
1.2
Number of wires
1
Min. bending radius
During handling and installation, cable mm
80
In final installation, cable mm
30
During handling and installation, cable cm
8
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
1.75
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,524
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006689
Reka code
1145738
50 BK H07Z1-R
Electric number
Size
Packaging
Voltage
50 BK H07Z1-R
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
504
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
94
In final installation, cable mm
35
During handling and installation, cable cm
9
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
2.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,387
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003336
Reka code
1145743
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
504
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
94
In final installation, cable mm
35
During handling and installation, cable cm
9
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
2.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,387
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006702
Reka code
1145743
50 BU H07Z1-R
Electric number
Size
Packaging
Voltage
50 BU H07Z1-R
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
504
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
94
In final installation, cable mm
35
During handling and installation, cable cm
9
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
2.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,387
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003374
Reka code
1145747
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
504
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
94
In final installation, cable mm
35
During handling and installation, cable cm
9
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
2.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,387
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006733
Reka code
1145747
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
504
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
94
In final installation, cable mm
35
During handling and installation, cable cm
9
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
2.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,387
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006726
Reka code
1145747
50 GNYE H07Z1-R
Electric number
Size
Packaging
Voltage
50 GNYE H07Z1-R
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
504
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
94
In final installation, cable mm
35
During handling and installation, cable cm
9
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
2.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,387
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003381
Reka code
1145748
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
504
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
94
In final installation, cable mm
35
During handling and installation, cable cm
9
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
2.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,387
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006740
Reka code
1145748
70 BK H07Z1-R
Electric number
Size
Packaging
Voltage
70 BK H07Z1-R
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
708
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
108
In final installation, cable mm
41
During handling and installation, cable cm
11
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
3.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,268
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006764
Reka code
1145753
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
708
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
108
In final installation, cable mm
41
During handling and installation, cable cm
11
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
3.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,268
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006771
Reka code
1145753
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
708
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
108
In final installation, cable mm
41
During handling and installation, cable cm
11
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
3.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,268
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003435
Reka code
1145753
70 BU H07Z1-R
Electric number
Size
Packaging
Voltage
70 BU H07Z1-R
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
708
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
108
In final installation, cable mm
41
During handling and installation, cable cm
11
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
3.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,268
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003473
Reka code
1145757
70 GNYE H07Z1-R
Electric number
Size
Packaging
Voltage
70 GNYE H07Z1-R
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
708
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
108
In final installation, cable mm
41
During handling and installation, cable cm
11
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
3.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,268
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003480
Reka code
1145758
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
708
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.4
Number of wires
1
Min. bending radius
During handling and installation, cable mm
108
In final installation, cable mm
41
During handling and installation, cable cm
11
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
3.5
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,268
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006788
Reka code
1145758
95 BK H07Z1-R
Electric number
Size
Packaging
Voltage
95 BK H07Z1-R
Nominal diameter of complete cable mm
16
Nominal weight of cable kg/km
987
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.6
Number of wires
1
Min. bending radius
During handling and installation, cable mm
126
In final installation, cable mm
47
During handling and installation, cable cm
13
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
4.75
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,193
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003534
Reka code
1145763
Nominal diameter of complete cable mm
16
Nominal weight of cable kg/km
987
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.6
Number of wires
1
Min. bending radius
During handling and installation, cable mm
126
In final installation, cable mm
47
During handling and installation, cable cm
13
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
4.75
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,193
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006801
Reka code
1145763
95 BU H07Z1-R
Electric number
Size
Packaging
Voltage
95 BU H07Z1-R
Nominal diameter of complete cable mm
16
Nominal weight of cable kg/km
987
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.6
Number of wires
1
Min. bending radius
During handling and installation, cable mm
126
In final installation, cable mm
47
During handling and installation, cable cm
13
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
4.75
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,193
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003572
Reka code
1145767
95 GNYE H07Z1-R
Electric number
Size
Packaging
Voltage
95 GNYE H07Z1-R
Nominal diameter of complete cable mm
16
Nominal weight of cable kg/km
987
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.6
Number of wires
1
Min. bending radius
During handling and installation, cable mm
126
In final installation, cable mm
47
During handling and installation, cable cm
13
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
4.75
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,193
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003589
Reka code
1145768
Nominal diameter of complete cable mm
16
Nominal weight of cable kg/km
987
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.6
Number of wires
1
Min. bending radius
During handling and installation, cable mm
126
In final installation, cable mm
47
During handling and installation, cable cm
13
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
4.75
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,193
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176006818
Reka code
1145768
120 BK H07Z1-R
Electric number
Size
Packaging
Voltage
120 BK H07Z1-R
Nominal diameter of complete cable mm
17
Nominal weight of cable kg/km
1223
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
120
Nominal thickness of insulation mm
1.6
Number of wires
1
Min. bending radius
During handling and installation, cable mm
139
In final installation, cable mm
52
During handling and installation, cable cm
14
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
6
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,153
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003633
Reka code
1145773
120 BU H07Z1-R
Electric number
Size
Packaging
Voltage
120 BU H07Z1-R
Nominal diameter of complete cable mm
17
Nominal weight of cable kg/km
1223
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
120
Nominal thickness of insulation mm
1.6
Number of wires
1
Min. bending radius
During handling and installation, cable mm
139
In final installation, cable mm
52
During handling and installation, cable cm
14
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
6
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,153
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003671
Reka code
1145777
120 GNYE H07Z1-R
Electric number
Size
Packaging
Voltage
120 GNYE H07Z1-R
Nominal diameter of complete cable mm
17
Nominal weight of cable kg/km
1223
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
120
Nominal thickness of insulation mm
1.6
Number of wires
1
Min. bending radius
During handling and installation, cable mm
139
In final installation, cable mm
52
During handling and installation, cable cm
14
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
6
Pulling-stocking kN
0
Resistance 20 °C Ω/km
0,153
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004003688
Reka code
1145778