MMJ-HF


Installation cable for fixed installations indoors and outdoors. Not to be laid in soil nor directly in cast concrete. Can be embedded to the groove filled with plaster. UV-protected oversheath and core insulation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.
Standards | SFS 5544, NEK 591 |
---|---|
Reaction to fire | Dca-s2,d2,a2 |
CPR - DoP | 2023001_DOP.pdf |
Conductor | Circular solid copper, EN/IEC 60228 class 1 |
Insulation | Polyethylene compound |
Core Identification (all color combinations in the cable family) | 2N: Blue, brown 3x: Brown, black, grey 3S: Yellow-green, blue, brown 4N: Blue, brown, black, grey 4S: Yellow-green, brown, black, grey 5N: Blue, brown, black, grey, black 5S: Yellow-green, blue, brown, black, grey |
Inner covering | Extruded filling compound |
Oversheath | UV-protected polyolefin compound |
Colour of the oversheath | White |
3x1,5 S
Electric number
Size
Packaging
Voltage
3x1,5 S
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
151
Conductor material
Copper
Nominal diameter of conductor mm
1.4
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
3
Min. bending radius
During handling and installation, cable mm
101
In final installation, cable mm
30
During handling and installation, cable cm
10
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.23
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164013
Reka code
1145056
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
151
Conductor material
Copper
Nominal diameter of conductor mm
1.4
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
3
Min. bending radius
During handling and installation, cable mm
101
In final installation, cable mm
30
During handling and installation, cable cm
10
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.23
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164006
Reka code
1145056
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
151
Conductor material
Copper
Nominal diameter of conductor mm
1.4
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
3
Min. bending radius
During handling and installation, cable mm
101
In final installation, cable mm
30
During handling and installation, cable cm
10
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.23
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164228
Reka code
1145056
Nominal diameter of complete cable mm
10
Nominal weight of cable kg/km
151
Conductor material
Copper
Nominal diameter of conductor mm
1.4
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
3
Min. bending radius
During handling and installation, cable mm
101
In final installation, cable mm
30
During handling and installation, cable cm
10
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.23
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164846
Reka code
1145056
5x1,5 S
Electric number
Size
Packaging
Voltage
5x1,5 S
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
203
Conductor material
Copper
Nominal diameter of conductor mm
1.4
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
5
Min. bending radius
During handling and installation, cable mm
121
In final installation, cable mm
36
During handling and installation, cable cm
12
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164426
Reka code
1145058
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
203
Conductor material
Copper
Nominal diameter of conductor mm
1.4
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
5
Min. bending radius
During handling and installation, cable mm
121
In final installation, cable mm
36
During handling and installation, cable cm
12
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164280
Reka code
1145058
Nominal diameter of complete cable mm
12
Nominal weight of cable kg/km
203
Conductor material
Copper
Nominal diameter of conductor mm
1.4
Nominal cross-sectional area of conductor mm2
1.5
Nominal thickness of insulation mm
0.7
Number of wires
5
Min. bending radius
During handling and installation, cable mm
121
In final installation, cable mm
36
During handling and installation, cable cm
12
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
12,1
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164860
Reka code
1145058
3x2,5 S
Electric number
Size
Packaging
Voltage
3x2,5 S
Nominal diameter of complete cable mm
11
Nominal weight of cable kg/km
202
Conductor material
Copper
Nominal diameter of conductor mm
1.7
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
3
Min. bending radius
During handling and installation, cable mm
114
In final installation, cable mm
34
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164853
Reka code
1145061
Nominal diameter of complete cable mm
11
Nominal weight of cable kg/km
202
Conductor material
Copper
Nominal diameter of conductor mm
1.7
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
3
Min. bending radius
During handling and installation, cable mm
114
In final installation, cable mm
34
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164235
Reka code
1145061
Nominal diameter of complete cable mm
11
Nominal weight of cable kg/km
202
Conductor material
Copper
Nominal diameter of conductor mm
1.7
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
3
Min. bending radius
During handling and installation, cable mm
114
In final installation, cable mm
34
During handling and installation, cable cm
11
In final installation, cable cm
3
Max. pulling force
Pulling-eye kN
0.38
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164044
Reka code
1145061
5x2,5 S
Electric number
Size
Packaging
Voltage
5x2,5 S
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
290
Conductor material
Copper
Nominal diameter of conductor mm
1.7
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
5
Min. bending radius
During handling and installation, cable mm
136
In final installation, cable mm
41
During handling and installation, cable cm
14
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.63
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164303
Reka code
1145063
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
290
Conductor material
Copper
Nominal diameter of conductor mm
1.7
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
5
Min. bending radius
During handling and installation, cable mm
136
In final installation, cable mm
41
During handling and installation, cable cm
14
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.63
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164877
Reka code
1145063
Nominal diameter of complete cable mm
14
Nominal weight of cable kg/km
290
Conductor material
Copper
Nominal diameter of conductor mm
1.7
Nominal cross-sectional area of conductor mm2
2.5
Nominal thickness of insulation mm
0.8
Number of wires
5
Min. bending radius
During handling and installation, cable mm
136
In final installation, cable mm
41
During handling and installation, cable cm
14
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.63
Resistance 20 °C Ω/km
7,41
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164433
Reka code
1145063
3x6 S
Electric number
Size
Packaging
Voltage
3x6 S
Nominal diameter of complete cable mm
15
Nominal weight of cable kg/km
402
Conductor material
Copper
Nominal diameter of conductor mm
3.2
Nominal cross-sectional area of conductor mm2
6
Nominal thickness of insulation mm
0.8
Number of wires
3
Min. bending radius
During handling and installation, cable mm
149
In final installation, cable mm
45
During handling and installation, cable cm
15
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.9
Resistance 20 °C Ω/km
3,08
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164273
Reka code
1145071
Nominal diameter of complete cable mm
15
Nominal weight of cable kg/km
402
Conductor material
Copper
Nominal diameter of conductor mm
3.2
Nominal cross-sectional area of conductor mm2
6
Nominal thickness of insulation mm
0.8
Number of wires
3
Min. bending radius
During handling and installation, cable mm
149
In final installation, cable mm
45
During handling and installation, cable cm
15
In final installation, cable cm
4
Max. pulling force
Pulling-eye kN
0.9
Resistance 20 °C Ω/km
3,08
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164259
Reka code
1145071
5x6 S
Electric number
Size
Packaging
Voltage
5x6 S
Nominal diameter of complete cable mm
18
Nominal weight of cable kg/km
593
Conductor material
Copper
Nominal diameter of conductor mm
3.2
Nominal cross-sectional area of conductor mm2
6
Nominal thickness of insulation mm
0.8
Number of wires
5
Min. bending radius
During handling and installation, cable mm
177
In final installation, cable mm
53
During handling and installation, cable cm
18
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
1.5
Resistance 20 °C Ω/km
3,08
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164457
Reka code
1145073
Nominal diameter of complete cable mm
18
Nominal weight of cable kg/km
593
Conductor material
Copper
Nominal diameter of conductor mm
3.2
Nominal cross-sectional area of conductor mm2
6
Nominal thickness of insulation mm
0.8
Number of wires
5
Min. bending radius
During handling and installation, cable mm
177
In final installation, cable mm
53
During handling and installation, cable cm
18
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
1.5
Resistance 20 °C Ω/km
3,08
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164310
Reka code
1145073
Nominal diameter of complete cable mm
18
Nominal weight of cable kg/km
593
Conductor material
Copper
Nominal diameter of conductor mm
3.2
Nominal cross-sectional area of conductor mm2
6
Nominal thickness of insulation mm
0.8
Number of wires
5
Min. bending radius
During handling and installation, cable mm
177
In final installation, cable mm
53
During handling and installation, cable cm
18
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
1.5
Resistance 20 °C Ω/km
3,08
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164327
Reka code
1145073
3x10 S
Electric number
Size
Packaging
Voltage
3x10 S
Nominal diameter of complete cable mm
18
Nominal weight of cable kg/km
602
Conductor material
Copper
Nominal diameter of conductor mm
4.1
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
1
Number of wires
3
Min. bending radius
During handling and installation, cable mm
179
In final installation, cable mm
54
During handling and installation, cable cm
18
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
1.5
Resistance 20 °C Ω/km
1,83
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176008386
Reka code
1145076
Nominal diameter of complete cable mm
18
Nominal weight of cable kg/km
602
Conductor material
Copper
Nominal diameter of conductor mm
4.1
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
1
Number of wires
3
Min. bending radius
During handling and installation, cable mm
179
In final installation, cable mm
54
During handling and installation, cable cm
18
In final installation, cable cm
5
Max. pulling force
Pulling-eye kN
1.5
Resistance 20 °C Ω/km
1,83
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164266
Reka code
1145076
5x10 S
Electric number
Size
Packaging
Voltage
5x10 S
Nominal diameter of complete cable mm
22
Nominal weight of cable kg/km
901
Conductor material
Copper
Nominal diameter of conductor mm
4.1
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
1
Number of wires
5
Min. bending radius
During handling and installation, cable mm
216
In final installation, cable mm
65
During handling and installation, cable cm
22
In final installation, cable cm
6
Max. pulling force
Pulling-eye kN
2.5
Resistance 20 °C Ω/km
1,83
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164341
Reka code
1145078
Nominal diameter of complete cable mm
22
Nominal weight of cable kg/km
901
Conductor material
Copper
Nominal diameter of conductor mm
4.1
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
1
Number of wires
5
Min. bending radius
During handling and installation, cable mm
216
In final installation, cable mm
65
During handling and installation, cable cm
22
In final installation, cable cm
6
Max. pulling force
Pulling-eye kN
2.5
Resistance 20 °C Ω/km
1,83
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164464
Reka code
1145078
Nominal diameter of complete cable mm
22
Nominal weight of cable kg/km
901
Conductor material
Copper
Nominal diameter of conductor mm
4.1
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
1
Number of wires
5
Min. bending radius
During handling and installation, cable mm
216
In final installation, cable mm
65
During handling and installation, cable cm
22
In final installation, cable cm
6
Max. pulling force
Pulling-eye kN
2.5
Resistance 20 °C Ω/km
1,83
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6410004164334
Reka code
1145078
5x16 S
Electric number
Size
Packaging
Voltage
5x16 S
Nominal diameter of complete cable mm
24
Nominal weight of cable kg/km
1259
Conductor material
Copper
Nominal diameter of conductor mm
5
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
1
Number of wires
5
Min. bending radius
During handling and installation, cable mm
244
In final installation, cable mm
73
During handling and installation, cable cm
24
In final installation, cable cm
7
Max. pulling force
Pulling-eye kN
4
Resistance 20 °C Ω/km
1,15
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176300060
Reka code
1145083
Nominal diameter of complete cable mm
24
Nominal weight of cable kg/km
1259
Conductor material
Copper
Nominal diameter of conductor mm
5
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
1
Number of wires
5
Min. bending radius
During handling and installation, cable mm
244
In final installation, cable mm
73
During handling and installation, cable cm
24
In final installation, cable cm
7
Max. pulling force
Pulling-eye kN
4
Resistance 20 °C Ω/km
1,15
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-40
Maximum conductor temperature in normal operation °C
70
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
160
EAN code
6438176008492
Reka code
1145083