TSLF 18/30 (36) kV 1-core CAS
Download product group datasheet
Medium-voltage cable for fixed installations outdoors. May be buried directly in soil. Cable is longitudinally and radially watertight and therefore it is suitable where wet soil and / or fresh water permanently occurs. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free, but without fire protection. The cable is not CPR-classified.
Standards | HD 620 10 K |
---|---|
Conductor | Watertight, circular, stranded aluminium, EN/IEC 60228 class 2 |
Conductor screen | Semiconducting cross-linked polyethylene XLPE |
Insulation | Cross-linked polyethylene XLPE |
Insulation screen | Semiconducting cross-linked polyethylene XLPE |
Metal screen | Copper wires and aluminium foil (CAS). Polyethylene laminated aluminium foil acts as a part of the metallic screen and needs to be connected in cable joints and terminations |
Radial watertightness | Polyethylene laminated aluminium foil bonded to the sheath |
Oversheath | PE-plastic PEMD |
Colour of the oversheath | Grey + black CL |
1x400/35 CAS
Electric number
Size
Packaging
Voltage
1x400/35 CAS
Nominal diameter of complete cable mm
48
Nominal weight of cable kg/km
2403
Conductor material
Aluminium
Nominal diameter of conductor mm
22.4
Nominal cross-sectional area of conductor mm2
400
Nominal thickness of insulation mm
8
Nominal diameter over the insulation without insulation screen mm
38
Number of wires
1
Nominal size of metal screen mm2
35
Nominal thickness of semi-conducting layer mm
0.3
Min. bending radius
During handling and installation, cable cm
72
In final installation, cable cm
51
During handling and installation, cable m
0.72
In final installation, cable m
0.51
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
6
Resistance 20 °C Ω/km
0,0778
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,524
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176014851
Reka code
1181233
1x630/50 CAS
Electric number
Size
Packaging
Voltage
1x630/50 CAS
Nominal diameter of complete cable mm
56
Nominal weight of cable kg/km
3574
Conductor material
Aluminium
Nominal diameter of conductor mm
29.3
Nominal cross-sectional area of conductor mm2
630
Nominal thickness of insulation mm
8
Nominal diameter over the insulation without insulation screen mm
45.1
Number of wires
1
Nominal size of metal screen mm2
50
Nominal thickness of semi-conducting layer mm
0.3
Min. bending radius
During handling and installation, cable cm
84
In final installation, cable cm
59
During handling and installation, cable m
0.84
In final installation, cable m
0.59
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0469
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,387
Minimum cable temperature during transport °C
-40
Minimum cable temperature during handling and installation °C
-20
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176014868
Reka code
1181235