XCMK-HF C / EXQJ C / FXQJ C / IFSI-Cu C

Download product group datasheet

Copper power cable for fixed installations indoors and outdoors. May be buried directly in soil. Can also be used in medical facilities where higher fire class is required. The conductor insulation must be protected against UV-radiation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free and flame-retardant according to CPR-class Cca-s1,d1,a1.

Standards SFS 5546, SS 424 14 18, HD 604 5 I & D, IEC 60502-1
Reaction to fire Cca-s1,d1,a1
CPR - DoP 2019010_DOP.pdf
2019009_DOP.pdf
Conductor 2,5-25 mm² circular stranded copper, EN/IEC 60228 class 2
35-300 mm² sector shaped stranded copper, EN/IEC 60228 class 2
Insulation Cross-linked polyethylene XLPE
Core Identification (all color combinations in the cable family) Blue, brown
Brown, black, grey
Blue, brown, black, grey
Inner covering Plastic tape
Metal screen Copper wires and copper tape
Oversheath UV-protected polyolefin compound
Colour of the oversheath Black

2x1,5/1,5

Electric number Size Packaging Voltage

2x1,5/1,5

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 191
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 14
In final installation, cable cm 10
During handling and installation, cable m 0.14
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301005
Reka code 1146403
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 191
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 14
In final installation, cable cm 10
During handling and installation, cable m 0.14
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301012
Reka code 1146403

2x2,5/2,5

Electric number Size Packaging Voltage

2x2,5/2,5

Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 239
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 15
In final installation, cable cm 11
During handling and installation, cable m 0.15
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301036
Reka code 1146404
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 239
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 15
In final installation, cable cm 11
During handling and installation, cable m 0.15
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301029
Reka code 1146404

2x4/4

Electric number Size Packaging Voltage

2x4/4

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 307
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.4
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301043
Reka code 1146405
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 307
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.4
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301050
Reka code 1146405

2x6/6

Electric number Size Packaging Voltage

2x6/6

Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 389
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 18
In final installation, cable cm 12
During handling and installation, cable m 0.18
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.6
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301067
Reka code 1146406
Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 389
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 18
In final installation, cable cm 12
During handling and installation, cable m 0.18
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.6
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301074
Reka code 1146406

2x10/10

Electric number Size Packaging Voltage

2x10/10

Nominal diameter of complete cable mm 18
Nominal weight of cable kg/km 570
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 21
In final installation, cable cm 15
During handling and installation, cable m 0.21
In final installation, cable m 0.15
Max. pulling force
Pulling-eye kN 1
Pulling-stocking kN 0.3
Resistance 20 °C Ω/km 1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,83
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301081
Reka code 1146407
Nominal diameter of complete cable mm 18
Nominal weight of cable kg/km 570
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 21
In final installation, cable cm 15
During handling and installation, cable m 0.21
In final installation, cable m 0.15
Max. pulling force
Pulling-eye kN 1
Pulling-stocking kN 0.3
Resistance 20 °C Ω/km 1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,83
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301098
Reka code 1146407

2x16/16

Electric number Size Packaging Voltage

2x16/16

Nominal diameter of complete cable mm 20
Nominal weight of cable kg/km 828
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 25
In final installation, cable cm 17
During handling and installation, cable m 0.25
In final installation, cable m 0.17
Max. pulling force
Pulling-eye kN 1.6
Pulling-stocking kN 0.5
Resistance 20 °C Ω/km 1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301111
Reka code 1146408
Nominal diameter of complete cable mm 20
Nominal weight of cable kg/km 828
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 0.7
Number of wires 2
Min. bending radius
During handling and installation, cable cm 25
In final installation, cable cm 17
During handling and installation, cable m 0.25
In final installation, cable m 0.17
Max. pulling force
Pulling-eye kN 1.6
Pulling-stocking kN 0.5
Resistance 20 °C Ω/km 1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301104
Reka code 1146408

2x25/16

Electric number Size Packaging Voltage

2x25/16

Nominal diameter of complete cable mm 24
Nominal weight of cable kg/km 1139
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 0.9
Number of wires 2
Min. bending radius
During handling and installation, cable cm 29
In final installation, cable cm 20
During handling and installation, cable m 0.29
In final installation, cable m 0.2
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0.8
Resistance 20 °C Ω/km 0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301135
Reka code 1146409
Nominal diameter of complete cable mm 24
Nominal weight of cable kg/km 1139
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 0.9
Number of wires 2
Min. bending radius
During handling and installation, cable cm 29
In final installation, cable cm 20
During handling and installation, cable m 0.29
In final installation, cable m 0.2
Max. pulling force
Pulling-eye kN 2.5
Pulling-stocking kN 0.8
Resistance 20 °C Ω/km 0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301128
Reka code 1146409

3x1,5/1,5

Electric number Size Packaging Voltage

3x1,5/1,5

Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 207
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 15
In final installation, cable cm 10
During handling and installation, cable m 0.15
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301142
Reka code 1146415
Nominal diameter of complete cable mm 12
Nominal weight of cable kg/km 207
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 15
In final installation, cable cm 10
During handling and installation, cable m 0.15
In final installation, cable m 0.1
Max. pulling force
Pulling-eye kN 0.2
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301159
Reka code 1146415

3x2,5/2,5

Electric number Size Packaging Voltage

3x2,5/2,5

Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 259
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 16
In final installation, cable cm 11
During handling and installation, cable m 0.16
In final installation, cable m 0.11
Max. pulling force
Pulling-eye kN 0.4
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301166
Reka code 1146416
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 259
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 16
In final installation, cable cm 11
During handling and installation, cable m 0.16
In final installation, cable m 0.11
Max. pulling force
Pulling-eye kN 0.4
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301173
Reka code 1146416

3x4/4

Electric number Size Packaging Voltage

3x4/4

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 343
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.6
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301197
Reka code 1146417
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 343
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.6
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301180
Reka code 1146417

3x6/6

Electric number Size Packaging Voltage

3x6/6

Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 442
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 19
In final installation, cable cm 13
During handling and installation, cable m 0.18
In final installation, cable m 0.13
Max. pulling force
Pulling-eye kN 0.9
Pulling-stocking kN 0.3
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301203
Reka code 1146418
Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 442
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 19
In final installation, cable cm 13
During handling and installation, cable m 0.18
In final installation, cable m 0.13
Max. pulling force
Pulling-eye kN 0.9
Pulling-stocking kN 0.3
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301210
Reka code 1146418

3x10/10

Electric number Size Packaging Voltage

3x10/10

Nominal diameter of complete cable mm 18
Nominal weight of cable kg/km 657
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 22
In final installation, cable cm 15
During handling and installation, cable m 0.22
In final installation, cable m 0.15
Max. pulling force
Pulling-eye kN 1.5
Pulling-stocking kN 0.5
Resistance 20 °C Ω/km 1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,83
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301227
Reka code 1146419
Nominal diameter of complete cable mm 18
Nominal weight of cable kg/km 657
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 22
In final installation, cable cm 15
During handling and installation, cable m 0.22
In final installation, cable m 0.15
Max. pulling force
Pulling-eye kN 1.5
Pulling-stocking kN 0.5
Resistance 20 °C Ω/km 1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,83
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301234
Reka code 1146419

3x16/16

Electric number Size Packaging Voltage

3x16/16

Nominal diameter of complete cable mm 21
Nominal weight of cable kg/km 960
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 26
In final installation, cable cm 18
During handling and installation, cable m 0.26
In final installation, cable m 0.18
Max. pulling force
Pulling-eye kN 2.4
Pulling-stocking kN 0.7
Resistance 20 °C Ω/km 1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301241
Reka code 1146420
Nominal diameter of complete cable mm 21
Nominal weight of cable kg/km 960
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 0.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 26
In final installation, cable cm 18
During handling and installation, cable m 0.26
In final installation, cable m 0.18
Max. pulling force
Pulling-eye kN 2.4
Pulling-stocking kN 0.7
Resistance 20 °C Ω/km 1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301258
Reka code 1146420

3x25/16

Electric number Size Packaging Voltage

3x25/16

Nominal diameter of complete cable mm 25
Nominal weight of cable kg/km 1338
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 0.9
Number of wires 3
Min. bending radius
During handling and installation, cable cm 30
In final installation, cable cm 21
During handling and installation, cable m 0.3
In final installation, cable m 0.21
Max. pulling force
Pulling-eye kN 3.8
Pulling-stocking kN 1.1
Resistance 20 °C Ω/km 0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301272
Reka code 1146421
Nominal diameter of complete cable mm 25
Nominal weight of cable kg/km 1338
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 0.9
Number of wires 3
Min. bending radius
During handling and installation, cable cm 30
In final installation, cable cm 21
During handling and installation, cable m 0.3
In final installation, cable m 0.21
Max. pulling force
Pulling-eye kN 3.8
Pulling-stocking kN 1.1
Resistance 20 °C Ω/km 0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301265
Reka code 1146421

3x35/16

Electric number Size Packaging Voltage

3x35/16

Nominal diameter of complete cable mm 23
Nominal weight of cable kg/km 1333
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 0.9
Number of wires 3
Min. bending radius
During handling and installation, cable cm 28
In final installation, cable cm 19
During handling and installation, cable m 0.28
In final installation, cable m 0.19
Max. pulling force
Pulling-eye kN 5.3
Pulling-stocking kN 1.6
Resistance 20 °C Ω/km 0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301296
Reka code 1146422
Nominal diameter of complete cable mm 23
Nominal weight of cable kg/km 1333
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 0.9
Number of wires 3
Min. bending radius
During handling and installation, cable cm 28
In final installation, cable cm 19
During handling and installation, cable m 0.28
In final installation, cable m 0.19
Max. pulling force
Pulling-eye kN 5.3
Pulling-stocking kN 1.6
Resistance 20 °C Ω/km 0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301289
Reka code 1146422

3x50/25

Electric number Size Packaging Voltage

3x50/25

Nominal diameter of complete cable mm 26
Nominal weight of cable kg/km 1821
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1
Number of wires 3
Min. bending radius
During handling and installation, cable cm 32
In final installation, cable cm 22
During handling and installation, cable m 0.32
In final installation, cable m 0.22
Max. pulling force
Pulling-eye kN 7.5
Pulling-stocking kN 2.3
Resistance 20 °C Ω/km 0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,727
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301319
Reka code 1146423
Nominal diameter of complete cable mm 26
Nominal weight of cable kg/km 1821
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1
Number of wires 3
Min. bending radius
During handling and installation, cable cm 32
In final installation, cable cm 22
During handling and installation, cable m 0.32
In final installation, cable m 0.22
Max. pulling force
Pulling-eye kN 7.5
Pulling-stocking kN 2.3
Resistance 20 °C Ω/km 0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,727
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301302
Reka code 1146423

3x70/35

Electric number Size Packaging Voltage

3x70/35

Nominal diameter of complete cable mm 30
Nominal weight of cable kg/km 2520
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.1
Number of wires 3
Min. bending radius
During handling and installation, cable cm 36
In final installation, cable cm 26
During handling and installation, cable m 0.36
In final installation, cable m 0.26
Max. pulling force
Pulling-eye kN 10.5
Pulling-stocking kN 3.2
Resistance 20 °C Ω/km 0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,524
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301333
Reka code 1146424
Nominal diameter of complete cable mm 30
Nominal weight of cable kg/km 2520
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.1
Number of wires 3
Min. bending radius
During handling and installation, cable cm 36
In final installation, cable cm 26
During handling and installation, cable m 0.36
In final installation, cable m 0.26
Max. pulling force
Pulling-eye kN 10.5
Pulling-stocking kN 3.2
Resistance 20 °C Ω/km 0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,524
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301326
Reka code 1146424

3x95/50

Electric number Size Packaging Voltage

3x95/50

Nominal diameter of complete cable mm 34
Nominal weight of cable kg/km 3406
Conductor material Copper
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 1.1
Number of wires 3
Min. bending radius
During handling and installation, cable cm 40
In final installation, cable cm 28
During handling and installation, cable m 0.4
In final installation, cable m 0.28
Max. pulling force
Pulling-eye kN 14.3
Pulling-stocking kN 4.3
Resistance 20 °C Ω/km 0,193
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,387
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301357
Reka code 1146425
Nominal diameter of complete cable mm 34
Nominal weight of cable kg/km 3406
Conductor material Copper
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 1.1
Number of wires 3
Min. bending radius
During handling and installation, cable cm 40
In final installation, cable cm 28
During handling and installation, cable m 0.4
In final installation, cable m 0.28
Max. pulling force
Pulling-eye kN 14.3
Pulling-stocking kN 4.3
Resistance 20 °C Ω/km 0,193
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,387
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301340
Reka code 1146425

3x120/70

Electric number Size Packaging Voltage

3x120/70

Nominal diameter of complete cable mm 36
Nominal weight of cable kg/km 4299
Conductor material Copper
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 1.2
Number of wires 3
Min. bending radius
During handling and installation, cable cm 44
In final installation, cable cm 31
During handling and installation, cable m 0.44
In final installation, cable m 0.31
Max. pulling force
Pulling-eye kN 18
Pulling-stocking kN 5.4
Resistance 20 °C Ω/km 0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,268
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301371
Reka code 1146426
Nominal diameter of complete cable mm 36
Nominal weight of cable kg/km 4299
Conductor material Copper
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 1.2
Number of wires 3
Min. bending radius
During handling and installation, cable cm 44
In final installation, cable cm 31
During handling and installation, cable m 0.44
In final installation, cable m 0.31
Max. pulling force
Pulling-eye kN 18
Pulling-stocking kN 5.4
Resistance 20 °C Ω/km 0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,268
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301364
Reka code 1146426

3x150/70

Electric number Size Packaging Voltage

3x150/70

Nominal diameter of complete cable mm 41
Nominal weight of cable kg/km 5201
Conductor material Copper
Nominal cross-sectional area of conductor mm2 150
Nominal thickness of insulation mm 1.4
Number of wires 3
Min. bending radius
During handling and installation, cable cm 49
In final installation, cable cm 34
During handling and installation, cable m 0.49
In final installation, cable m 0.34
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 6.8
Resistance 20 °C Ω/km 0,124
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,268
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301388
Reka code 1146427

3x185/95

Electric number Size Packaging Voltage

3x185/95

Nominal diameter of complete cable mm 45
Nominal weight of cable kg/km 6563
Conductor material Copper
Nominal cross-sectional area of conductor mm2 185
Nominal thickness of insulation mm 1.6
Number of wires 3
Min. bending radius
During handling and installation, cable cm 54
In final installation, cable cm 38
During handling and installation, cable m 0.54
In final installation, cable m 0.38
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.3
Resistance 20 °C Ω/km 0,0991
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,193
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301395
Reka code 1146428

3x240/120

Electric number Size Packaging Voltage

3x240/120

Nominal diameter of complete cable mm 53
Nominal weight of cable kg/km 8568
Conductor material Copper
Nominal cross-sectional area of conductor mm2 240
Nominal thickness of insulation mm 1.7
Number of wires 3
Min. bending radius
During handling and installation, cable cm 63
In final installation, cable cm 44
During handling and installation, cable m 0.64
In final installation, cable m 0.44
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,0754
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,153
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301401
Reka code 1146429

3x300/150

Electric number Size Packaging Voltage

3x300/150

Nominal diameter of complete cable mm 56
Nominal weight of cable kg/km 10608
Conductor material Copper
Nominal cross-sectional area of conductor mm2 300
Nominal thickness of insulation mm 1.8
Number of wires 3
Min. bending radius
During handling and installation, cable cm 67
In final installation, cable cm 47
During handling and installation, cable m 0.67
In final installation, cable m 0.47
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,0601
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,124
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301418
Reka code 1146430

4x1,5/1,5

Electric number Size Packaging Voltage

4x1,5/1,5

Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 234
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 16
In final installation, cable cm 11
During handling and installation, cable m 0.15
In final installation, cable m 0.11
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301432
Reka code 1146435
Nominal diameter of complete cable mm 13
Nominal weight of cable kg/km 234
Conductor material Copper
Nominal cross-sectional area of conductor mm2 1.5
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 16
In final installation, cable cm 11
During handling and installation, cable m 0.15
In final installation, cable m 0.11
Max. pulling force
Pulling-eye kN 0.3
Pulling-stocking kN 0.1
Resistance 20 °C Ω/km 12,1
Maximum d.c. resistance at 20 °C, metal screen Ω/km 12,1
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301425
Reka code 1146435

4x2,5/2,5

Electric number Size Packaging Voltage

4x2,5/2,5

Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 296
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301456
Reka code 1146436
Nominal diameter of complete cable mm 14
Nominal weight of cable kg/km 296
Conductor material Copper
Nominal cross-sectional area of conductor mm2 2.5
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 17
In final installation, cable cm 12
During handling and installation, cable m 0.17
In final installation, cable m 0.12
Max. pulling force
Pulling-eye kN 0.5
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 7,41
Maximum d.c. resistance at 20 °C, metal screen Ω/km 7,41
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301449
Reka code 1146436

4x4/4

Electric number Size Packaging Voltage

4x4/4

Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 398
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 18
In final installation, cable cm 13
During handling and installation, cable m 0.18
In final installation, cable m 0.13
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301470
Reka code 1146437
Nominal diameter of complete cable mm 15
Nominal weight of cable kg/km 398
Conductor material Copper
Nominal cross-sectional area of conductor mm2 4
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 18
In final installation, cable cm 13
During handling and installation, cable m 0.18
In final installation, cable m 0.13
Max. pulling force
Pulling-eye kN 0.8
Pulling-stocking kN 0.2
Resistance 20 °C Ω/km 4,61
Maximum d.c. resistance at 20 °C, metal screen Ω/km 4,61
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301463
Reka code 1146437

4x6/6

Electric number Size Packaging Voltage

4x6/6

Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 520
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 20
In final installation, cable cm 14
During handling and installation, cable m 0.2
In final installation, cable m 0.14
Max. pulling force
Pulling-eye kN 1.2
Pulling-stocking kN 0.4
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301494
Reka code 1146438
Nominal diameter of complete cable mm 17
Nominal weight of cable kg/km 520
Conductor material Copper
Nominal cross-sectional area of conductor mm2 6
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 20
In final installation, cable cm 14
During handling and installation, cable m 0.2
In final installation, cable m 0.14
Max. pulling force
Pulling-eye kN 1.2
Pulling-stocking kN 0.4
Resistance 20 °C Ω/km 3,08
Maximum d.c. resistance at 20 °C, metal screen Ω/km 3,08
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301487
Reka code 1146438

4x10/10

Electric number Size Packaging Voltage

4x10/10

Nominal diameter of complete cable mm 20
Nominal weight of cable kg/km 801
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 24
In final installation, cable cm 17
During handling and installation, cable m 0.24
In final installation, cable m 0.17
Max. pulling force
Pulling-eye kN 2
Pulling-stocking kN 0.6
Resistance 20 °C Ω/km 1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,83
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301500
Reka code 1146439
Nominal diameter of complete cable mm 20
Nominal weight of cable kg/km 801
Conductor material Copper
Nominal cross-sectional area of conductor mm2 10
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 24
In final installation, cable cm 17
During handling and installation, cable m 0.24
In final installation, cable m 0.17
Max. pulling force
Pulling-eye kN 2
Pulling-stocking kN 0.6
Resistance 20 °C Ω/km 1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,83
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301517
Reka code 1146439

4x16/16

Electric number Size Packaging Voltage

4x16/16

Nominal diameter of complete cable mm 23
Nominal weight of cable kg/km 1142
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 28
In final installation, cable cm 19
During handling and installation, cable m 0.28
In final installation, cable m 0.19
Max. pulling force
Pulling-eye kN 3.2
Pulling-stocking kN 1
Resistance 20 °C Ω/km 1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301524
Reka code 1146440
Nominal diameter of complete cable mm 23
Nominal weight of cable kg/km 1142
Conductor material Copper
Nominal cross-sectional area of conductor mm2 16
Nominal thickness of insulation mm 0.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 28
In final installation, cable cm 19
During handling and installation, cable m 0.28
In final installation, cable m 0.19
Max. pulling force
Pulling-eye kN 3.2
Pulling-stocking kN 1
Resistance 20 °C Ω/km 1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301531
Reka code 1146440

4x25/16

Electric number Size Packaging Voltage

4x25/16

Nominal diameter of complete cable mm 27
Nominal weight of cable kg/km 1616
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 0.9
Number of wires 4
Min. bending radius
During handling and installation, cable cm 33
In final installation, cable cm 23
During handling and installation, cable m 0.33
In final installation, cable m 0.23
Max. pulling force
Pulling-eye kN 5
Pulling-stocking kN 1.5
Resistance 20 °C Ω/km 0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301548
Reka code 1146441
Nominal diameter of complete cable mm 27
Nominal weight of cable kg/km 1616
Conductor material Copper
Nominal cross-sectional area of conductor mm2 25
Nominal thickness of insulation mm 0.9
Number of wires 4
Min. bending radius
During handling and installation, cable cm 33
In final installation, cable cm 23
During handling and installation, cable m 0.33
In final installation, cable m 0.23
Max. pulling force
Pulling-eye kN 5
Pulling-stocking kN 1.5
Resistance 20 °C Ω/km 0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301555
Reka code 1146441

4x35/16

Electric number Size Packaging Voltage

4x35/16

Nominal diameter of complete cable mm 26
Nominal weight of cable kg/km 1690
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 0.9
Number of wires 4
Min. bending radius
During handling and installation, cable cm 31
In final installation, cable cm 22
During handling and installation, cable m 0.31
In final installation, cable m 0.22
Max. pulling force
Pulling-eye kN 7
Pulling-stocking kN 2.1
Resistance 20 °C Ω/km 0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301562
Reka code 1146442
Nominal diameter of complete cable mm 26
Nominal weight of cable kg/km 1690
Conductor material Copper
Nominal cross-sectional area of conductor mm2 35
Nominal thickness of insulation mm 0.9
Number of wires 4
Min. bending radius
During handling and installation, cable cm 31
In final installation, cable cm 22
During handling and installation, cable m 0.31
In final installation, cable m 0.22
Max. pulling force
Pulling-eye kN 7
Pulling-stocking kN 2.1
Resistance 20 °C Ω/km 0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km 1,15
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301579
Reka code 1146442

4x50/25

Electric number Size Packaging Voltage

4x50/25

Nominal diameter of complete cable mm 30
Nominal weight of cable kg/km 2319
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1
Number of wires 4
Min. bending radius
During handling and installation, cable cm 35
In final installation, cable cm 25
During handling and installation, cable m 0.35
In final installation, cable m 0.25
Max. pulling force
Pulling-eye kN 10
Pulling-stocking kN 3
Resistance 20 °C Ω/km 0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,727
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301593
Reka code 1146443
Nominal diameter of complete cable mm 30
Nominal weight of cable kg/km 2319
Conductor material Copper
Nominal cross-sectional area of conductor mm2 50
Nominal thickness of insulation mm 1
Number of wires 4
Min. bending radius
During handling and installation, cable cm 35
In final installation, cable cm 25
During handling and installation, cable m 0.35
In final installation, cable m 0.25
Max. pulling force
Pulling-eye kN 10
Pulling-stocking kN 3
Resistance 20 °C Ω/km 0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,727
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301586
Reka code 1146443

4x70/35

Electric number Size Packaging Voltage

4x70/35

Nominal diameter of complete cable mm 34
Nominal weight of cable kg/km 3208
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.1
Number of wires 4
Min. bending radius
During handling and installation, cable cm 41
In final installation, cable cm 29
During handling and installation, cable m 0.41
In final installation, cable m 0.29
Max. pulling force
Pulling-eye kN 14
Pulling-stocking kN 4.2
Resistance 20 °C Ω/km 0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,524
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301616
Reka code 1146444
Nominal diameter of complete cable mm 34
Nominal weight of cable kg/km 3208
Conductor material Copper
Nominal cross-sectional area of conductor mm2 70
Nominal thickness of insulation mm 1.1
Number of wires 4
Min. bending radius
During handling and installation, cable cm 41
In final installation, cable cm 29
During handling and installation, cable m 0.41
In final installation, cable m 0.29
Max. pulling force
Pulling-eye kN 14
Pulling-stocking kN 4.2
Resistance 20 °C Ω/km 0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,524
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301609
Reka code 1146444

4x95/50

Electric number Size Packaging Voltage

4x95/50

Nominal diameter of complete cable mm 38
Nominal weight of cable kg/km 4329
Conductor material Copper
Nominal cross-sectional area of conductor mm2 95
Nominal thickness of insulation mm 1.1
Number of wires 4
Min. bending radius
During handling and installation, cable cm 45
In final installation, cable cm 32
During handling and installation, cable m 0.45
In final installation, cable m 0.32
Max. pulling force
Pulling-eye kN 19
Pulling-stocking kN 5.7
Resistance 20 °C Ω/km 0,193
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,387
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301623
Reka code 1146445

4x120/70

Electric number Size Packaging Voltage

4x120/70

Nominal diameter of complete cable mm 42
Nominal weight of cable kg/km 5495
Conductor material Copper
Nominal cross-sectional area of conductor mm2 120
Nominal thickness of insulation mm 1.2
Number of wires 4
Min. bending radius
During handling and installation, cable cm 50
In final installation, cable cm 35
During handling and installation, cable m 0.5
In final installation, cable m 0.35
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 7.2
Resistance 20 °C Ω/km 0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,268
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301630
Reka code 1146446

4x150/70

Electric number Size Packaging Voltage

4x150/70

Nominal diameter of complete cable mm 46
Nominal weight of cable kg/km 6639
Conductor material Copper
Nominal cross-sectional area of conductor mm2 150
Nominal thickness of insulation mm 1.4
Number of wires 4
Min. bending radius
During handling and installation, cable cm 55
In final installation, cable cm 38
During handling and installation, cable m 0.55
In final installation, cable m 0.38
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,124
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,268
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301647
Reka code 1146447

4x185/95

Electric number Size Packaging Voltage

4x185/95

Nominal diameter of complete cable mm 51
Nominal weight of cable kg/km 8382
Conductor material Copper
Nominal cross-sectional area of conductor mm2 185
Nominal thickness of insulation mm 1.6
Number of wires 4
Min. bending radius
During handling and installation, cable cm 61
In final installation, cable cm 43
During handling and installation, cable m 0.61
In final installation, cable m 0.43
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,0991
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,193
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301654
Reka code 1146448

4x240/120

Electric number Size Packaging Voltage

4x240/120

Nominal diameter of complete cable mm 57
Nominal weight of cable kg/km 10904
Conductor material Copper
Nominal cross-sectional area of conductor mm2 240
Nominal thickness of insulation mm 1.7
Number of wires 4
Min. bending radius
During handling and installation, cable cm 68
In final installation, cable cm 48
During handling and installation, cable m 0.68
In final installation, cable m 0.48
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,0754
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,153
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301661
Reka code 1146449

4x300/150

Electric number Size Packaging Voltage

4x300/150

Nominal diameter of complete cable mm 61
Nominal weight of cable kg/km 13554
Conductor material Copper
Nominal cross-sectional area of conductor mm2 300
Nominal thickness of insulation mm 1.8
Number of wires 4
Min. bending radius
During handling and installation, cable cm 73
In final installation, cable cm 51
During handling and installation, cable m 0.73
In final installation, cable m 0.51
Max. pulling force
Pulling-eye kN 20
Pulling-stocking kN 8.5
Resistance 20 °C Ω/km 0,0601
Maximum d.c. resistance at 20 °C, metal screen Ω/km 0,124
Minimum cable temperature during transport °C -25
Minimum cable temperature during handling and installation °C -15
Minimum cable temperature during operation °C -50
Maximum conductor temperature in normal operation °C 90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C 250
EAN code 6438176301678
Reka code 1146450