XCMK-HF / FXQJ / IFSI-Cu
Download product group datasheet
Copper power cable for fixed installations indoors and outdoors. May be buried directly in soil. The conductor insulation must be protected against UV-radiation. Installations must be in accordance with national regulations and rules of installations. The cable is halogen-free and flame-retardant according to CPR-class Dca-s2,d2,a2.
Standards | SFS 5546, SEK TS 424 14 18-1, HD 604 5 I & D, IEC 60502-1 |
---|---|
Reaction to fire | Dca-s2,d2,a2 |
CPR - DoP | 2021012_DOP.pdf 2021003_DOP.pdf |
Conductor | 2,5-25 mm² circular stranded copper, EN/IEC 60228 class 2 35-300 mm² sector shaped stranded copper, EN/IEC 60228 class 2 |
Insulation | Cross-linked polyethylene XLPE |
Core Identification (all color combinations in the cable family) | Blue, brown Brown, black, grey Blue, brown, black, grey |
Inner covering | Extruded filling compound |
Metal screen | Copper wires and copper tape |
Oversheath | UV-protected polyolefin compound |
Colour of the oversheath | Black |
2x10/10
Electric number
Size
Packaging
Voltage
2x10/10
Nominal diameter of complete cable mm
18
Nominal weight of cable kg/km
563
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
0.7
Number of wires
2
Min. bending radius
During handling and installation, cable cm
21
In final installation, cable cm
15
During handling and installation, cable m
0.21
In final installation, cable m
0.15
Max. pulling force
Pulling-eye kN
1
Pulling-stocking kN
0.3
Resistance 20 °C Ω/km
1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,83
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006029914
Reka code
1146109
Nominal diameter of complete cable mm
18
Nominal weight of cable kg/km
563
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
0.7
Number of wires
2
Min. bending radius
During handling and installation, cable cm
21
In final installation, cable cm
15
During handling and installation, cable m
0.21
In final installation, cable m
0.15
Max. pulling force
Pulling-eye kN
1
Pulling-stocking kN
0.3
Resistance 20 °C Ω/km
1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,83
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176011645
Reka code
1146109
2x16/16
Electric number
Size
Packaging
Voltage
2x16/16
Nominal diameter of complete cable mm
20
Nominal weight of cable kg/km
821
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
0.7
Number of wires
2
Min. bending radius
During handling and installation, cable cm
25
In final installation, cable cm
17
During handling and installation, cable m
0.25
In final installation, cable m
0.17
Max. pulling force
Pulling-eye kN
1.6
Pulling-stocking kN
0.5
Resistance 20 °C Ω/km
1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176011652
Reka code
1146110
Nominal diameter of complete cable mm
20
Nominal weight of cable kg/km
821
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
0.7
Number of wires
2
Min. bending radius
During handling and installation, cable cm
25
In final installation, cable cm
17
During handling and installation, cable m
0.25
In final installation, cable m
0.17
Max. pulling force
Pulling-eye kN
1.6
Pulling-stocking kN
0.5
Resistance 20 °C Ω/km
1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006029921
Reka code
1146110
2x25/16
Electric number
Size
Packaging
Voltage
2x25/16
Nominal diameter of complete cable mm
24
Nominal weight of cable kg/km
1130
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
0.9
Number of wires
2
Min. bending radius
During handling and installation, cable cm
29
In final installation, cable cm
20
During handling and installation, cable m
0.29
In final installation, cable m
0.2
Max. pulling force
Pulling-eye kN
2.5
Pulling-stocking kN
0.8
Resistance 20 °C Ω/km
0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176011669
Reka code
1146111
2x35/16
Electric number
Size
Packaging
Voltage
2x35/16
Nominal diameter of complete cable mm
25
Nominal weight of cable kg/km
1274
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
0.9
Number of wires
2
Min. bending radius
During handling and installation, cable cm
30
In final installation, cable cm
21
During handling and installation, cable m
0.3
In final installation, cable m
0.21
Max. pulling force
Pulling-eye kN
3.5
Pulling-stocking kN
1.1
Resistance 20 °C Ω/km
0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176011676
Reka code
1146112
3x10/10
Electric number
Size
Packaging
Voltage
3x10/10
Nominal diameter of complete cable mm
18
Nominal weight of cable kg/km
651
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
0.7
Number of wires
3
Min. bending radius
During handling and installation, cable cm
22
In final installation, cable cm
15
During handling and installation, cable m
0.22
In final installation, cable m
0.15
Max. pulling force
Pulling-eye kN
1.5
Pulling-stocking kN
0.5
Resistance 20 °C Ω/km
1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,83
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023684
Reka code
1146229
Nominal diameter of complete cable mm
18
Nominal weight of cable kg/km
651
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
0.7
Number of wires
3
Min. bending radius
During handling and installation, cable cm
22
In final installation, cable cm
15
During handling and installation, cable m
0.22
In final installation, cable m
0.15
Max. pulling force
Pulling-eye kN
1.5
Pulling-stocking kN
0.5
Resistance 20 °C Ω/km
1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,83
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023349
Reka code
1146229
3x16/16
Electric number
Size
Packaging
Voltage
3x16/16
Nominal diameter of complete cable mm
21
Nominal weight of cable kg/km
952
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
0.7
Number of wires
3
Min. bending radius
During handling and installation, cable cm
26
In final installation, cable cm
18
During handling and installation, cable m
0.26
In final installation, cable m
0.18
Max. pulling force
Pulling-eye kN
2.4
Pulling-stocking kN
0.7
Resistance 20 °C Ω/km
1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023387
Reka code
1146230
Nominal diameter of complete cable mm
21
Nominal weight of cable kg/km
952
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
0.7
Number of wires
3
Min. bending radius
During handling and installation, cable cm
26
In final installation, cable cm
18
During handling and installation, cable m
0.26
In final installation, cable m
0.18
Max. pulling force
Pulling-eye kN
2.4
Pulling-stocking kN
0.7
Resistance 20 °C Ω/km
1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023394
Reka code
1146230
3x25/16
Electric number
Size
Packaging
Voltage
3x25/16
Nominal diameter of complete cable mm
25
Nominal weight of cable kg/km
1313
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
0.9
Number of wires
3
Min. bending radius
During handling and installation, cable cm
30
In final installation, cable cm
21
During handling and installation, cable m
0.3
In final installation, cable m
0.21
Max. pulling force
Pulling-eye kN
3.8
Pulling-stocking kN
1.1
Resistance 20 °C Ω/km
0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023400
Reka code
1146231
Nominal diameter of complete cable mm
25
Nominal weight of cable kg/km
1313
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
0.9
Number of wires
3
Min. bending radius
During handling and installation, cable cm
30
In final installation, cable cm
21
During handling and installation, cable m
0.3
In final installation, cable m
0.21
Max. pulling force
Pulling-eye kN
3.8
Pulling-stocking kN
1.1
Resistance 20 °C Ω/km
0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023417
Reka code
1146231
3x35/16
Electric number
Size
Packaging
Voltage
3x35/16
Nominal diameter of complete cable mm
23
Nominal weight of cable kg/km
1328
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
0.9
Number of wires
3
Min. bending radius
During handling and installation, cable cm
28
In final installation, cable cm
19
During handling and installation, cable m
0.28
In final installation, cable m
0.19
Max. pulling force
Pulling-eye kN
5.3
Pulling-stocking kN
1.6
Resistance 20 °C Ω/km
0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023424
Reka code
1146232
Nominal diameter of complete cable mm
23
Nominal weight of cable kg/km
1328
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
0.9
Number of wires
3
Min. bending radius
During handling and installation, cable cm
28
In final installation, cable cm
19
During handling and installation, cable m
0.28
In final installation, cable m
0.19
Max. pulling force
Pulling-eye kN
5.3
Pulling-stocking kN
1.6
Resistance 20 °C Ω/km
0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023431
Reka code
1146232
3x50/25
Electric number
Size
Packaging
Voltage
3x50/25
Nominal diameter of complete cable mm
26
Nominal weight of cable kg/km
1815
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1
Number of wires
3
Min. bending radius
During handling and installation, cable cm
32
In final installation, cable cm
22
During handling and installation, cable m
0.32
In final installation, cable m
0.22
Max. pulling force
Pulling-eye kN
7.5
Pulling-stocking kN
2.3
Resistance 20 °C Ω/km
0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,727
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023448
Reka code
1146233
Nominal diameter of complete cable mm
26
Nominal weight of cable kg/km
1815
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1
Number of wires
3
Min. bending radius
During handling and installation, cable cm
32
In final installation, cable cm
22
During handling and installation, cable m
0.32
In final installation, cable m
0.22
Max. pulling force
Pulling-eye kN
7.5
Pulling-stocking kN
2.3
Resistance 20 °C Ω/km
0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,727
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023455
Reka code
1146233
3x120/70
Electric number
Size
Packaging
Voltage
3x120/70
Nominal diameter of complete cable mm
37
Nominal weight of cable kg/km
4304
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
120
Nominal thickness of insulation mm
1.2
Number of wires
3
Min. bending radius
During handling and installation, cable cm
44
In final installation, cable cm
31
During handling and installation, cable m
0.44
In final installation, cable m
0.31
Max. pulling force
Pulling-eye kN
18
Pulling-stocking kN
5.4
Resistance 20 °C Ω/km
0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023509
Reka code
1146236
Nominal diameter of complete cable mm
37
Nominal weight of cable kg/km
4304
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
120
Nominal thickness of insulation mm
1.2
Number of wires
3
Min. bending radius
During handling and installation, cable cm
44
In final installation, cable cm
31
During handling and installation, cable m
0.44
In final installation, cable m
0.31
Max. pulling force
Pulling-eye kN
18
Pulling-stocking kN
5.4
Resistance 20 °C Ω/km
0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023516
Reka code
1146236
3x150/70
Electric number
Size
Packaging
Voltage
3x150/70
Nominal diameter of complete cable mm
41
Nominal weight of cable kg/km
5189
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
150
Nominal thickness of insulation mm
1.4
Number of wires
3
Min. bending radius
During handling and installation, cable cm
49
In final installation, cable cm
34
During handling and installation, cable m
0.49
In final installation, cable m
0.34
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
6.8
Resistance 20 °C Ω/km
0,124
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023561
Reka code
1146237
Nominal diameter of complete cable mm
41
Nominal weight of cable kg/km
5189
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
150
Nominal thickness of insulation mm
1.4
Number of wires
3
Min. bending radius
During handling and installation, cable cm
49
In final installation, cable cm
34
During handling and installation, cable m
0.49
In final installation, cable m
0.34
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
6.8
Resistance 20 °C Ω/km
0,124
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023523
Reka code
1146237
3x185/95
Electric number
Size
Packaging
Voltage
3x185/95
Nominal diameter of complete cable mm
45
Nominal weight of cable kg/km
6550
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
185
Nominal thickness of insulation mm
1.6
Number of wires
3
Min. bending radius
During handling and installation, cable cm
54
In final installation, cable cm
38
During handling and installation, cable m
0.54
In final installation, cable m
0.38
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.3
Resistance 20 °C Ω/km
0,0991
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,193
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023585
Reka code
1146238
Nominal diameter of complete cable mm
45
Nominal weight of cable kg/km
6550
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
185
Nominal thickness of insulation mm
1.6
Number of wires
3
Min. bending radius
During handling and installation, cable cm
54
In final installation, cable cm
38
During handling and installation, cable m
0.54
In final installation, cable m
0.38
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.3
Resistance 20 °C Ω/km
0,0991
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,193
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023578
Reka code
1146238
3x240/120
Electric number
Size
Packaging
Voltage
3x240/120
Nominal diameter of complete cable mm
53
Nominal weight of cable kg/km
8551
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
240
Nominal thickness of insulation mm
1.7
Number of wires
3
Min. bending radius
During handling and installation, cable cm
63
In final installation, cable cm
44
During handling and installation, cable m
0.64
In final installation, cable m
0.44
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0754
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,153
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023608
Reka code
1146239
Nominal diameter of complete cable mm
53
Nominal weight of cable kg/km
8551
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
240
Nominal thickness of insulation mm
1.7
Number of wires
3
Min. bending radius
During handling and installation, cable cm
63
In final installation, cable cm
44
During handling and installation, cable m
0.64
In final installation, cable m
0.44
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0754
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,153
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023592
Reka code
1146239
4x10/10
Electric number
Size
Packaging
Voltage
4x10/10
Nominal diameter of complete cable mm
20
Nominal weight of cable kg/km
801
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
0.7
Number of wires
4
Min. bending radius
During handling and installation, cable cm
24
In final installation, cable cm
17
During handling and installation, cable m
0.24
In final installation, cable m
0.17
Max. pulling force
Pulling-eye kN
2
Pulling-stocking kN
0.6
Resistance 20 °C Ω/km
1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,83
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023226
Reka code
1146309
Nominal diameter of complete cable mm
20
Nominal weight of cable kg/km
801
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
10
Nominal thickness of insulation mm
0.7
Number of wires
4
Min. bending radius
During handling and installation, cable cm
24
In final installation, cable cm
17
During handling and installation, cable m
0.24
In final installation, cable m
0.17
Max. pulling force
Pulling-eye kN
2
Pulling-stocking kN
0.6
Resistance 20 °C Ω/km
1,83
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,83
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023233
Reka code
1146309
4x16/16
Electric number
Size
Packaging
Voltage
4x16/16
Nominal diameter of complete cable mm
23
Nominal weight of cable kg/km
1137
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
0.7
Number of wires
4
Min. bending radius
During handling and installation, cable cm
28
In final installation, cable cm
19
During handling and installation, cable m
0.28
In final installation, cable m
0.19
Max. pulling force
Pulling-eye kN
3.2
Pulling-stocking kN
1
Resistance 20 °C Ω/km
1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023271
Reka code
1146310
Nominal diameter of complete cable mm
23
Nominal weight of cable kg/km
1137
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
16
Nominal thickness of insulation mm
0.7
Number of wires
4
Min. bending radius
During handling and installation, cable cm
28
In final installation, cable cm
19
During handling and installation, cable m
0.28
In final installation, cable m
0.19
Max. pulling force
Pulling-eye kN
3.2
Pulling-stocking kN
1
Resistance 20 °C Ω/km
1,15
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023240
Reka code
1146310
4x25/16
Electric number
Size
Packaging
Voltage
4x25/16
Nominal diameter of complete cable mm
28
Nominal weight of cable kg/km
1590
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
0.9
Number of wires
4
Min. bending radius
During handling and installation, cable cm
33
In final installation, cable cm
23
During handling and installation, cable m
0.33
In final installation, cable m
0.23
Max. pulling force
Pulling-eye kN
5
Pulling-stocking kN
1.5
Resistance 20 °C Ω/km
0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023264
Reka code
1146311
Nominal diameter of complete cable mm
28
Nominal weight of cable kg/km
1590
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
25
Nominal thickness of insulation mm
0.9
Number of wires
4
Min. bending radius
During handling and installation, cable cm
33
In final installation, cable cm
23
During handling and installation, cable m
0.33
In final installation, cable m
0.23
Max. pulling force
Pulling-eye kN
5
Pulling-stocking kN
1.5
Resistance 20 °C Ω/km
0,727
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023288
Reka code
1146311
4x35/16
Electric number
Size
Packaging
Voltage
4x35/16
Nominal diameter of complete cable mm
26
Nominal weight of cable kg/km
1684
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
0.9
Number of wires
4
Min. bending radius
During handling and installation, cable cm
31
In final installation, cable cm
22
During handling and installation, cable m
0.31
In final installation, cable m
0.22
Max. pulling force
Pulling-eye kN
7
Pulling-stocking kN
2.1
Resistance 20 °C Ω/km
0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176219775
Reka code
1146312
Nominal diameter of complete cable mm
26
Nominal weight of cable kg/km
1684
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
35
Nominal thickness of insulation mm
0.9
Number of wires
4
Min. bending radius
During handling and installation, cable cm
31
In final installation, cable cm
22
During handling and installation, cable m
0.31
In final installation, cable m
0.22
Max. pulling force
Pulling-eye kN
7
Pulling-stocking kN
2.1
Resistance 20 °C Ω/km
0,524
Maximum d.c. resistance at 20 °C, metal screen Ω/km
1,15
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023295
Reka code
1146312
4x50/25
Electric number
Size
Packaging
Voltage
4x50/25
Nominal diameter of complete cable mm
30
Nominal weight of cable kg/km
2312
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
35
In final installation, cable cm
25
During handling and installation, cable m
0.35
In final installation, cable m
0.25
Max. pulling force
Pulling-eye kN
10
Pulling-stocking kN
3
Resistance 20 °C Ω/km
0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,727
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023677
Reka code
1146313
Nominal diameter of complete cable mm
30
Nominal weight of cable kg/km
2312
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
50
Nominal thickness of insulation mm
1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
35
In final installation, cable cm
25
During handling and installation, cable m
0.35
In final installation, cable m
0.25
Max. pulling force
Pulling-eye kN
10
Pulling-stocking kN
3
Resistance 20 °C Ω/km
0,387
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,727
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023660
Reka code
1146313
4x70/35
Electric number
Size
Packaging
Voltage
4x70/35
Nominal diameter of complete cable mm
34
Nominal weight of cable kg/km
3199
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
41
In final installation, cable cm
29
During handling and installation, cable m
0.41
In final installation, cable m
0.29
Max. pulling force
Pulling-eye kN
14
Pulling-stocking kN
4.2
Resistance 20 °C Ω/km
0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,524
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023318
Reka code
1146314
Nominal diameter of complete cable mm
34
Nominal weight of cable kg/km
3199
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
70
Nominal thickness of insulation mm
1.1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
41
In final installation, cable cm
29
During handling and installation, cable m
0.41
In final installation, cable m
0.29
Max. pulling force
Pulling-eye kN
14
Pulling-stocking kN
4.2
Resistance 20 °C Ω/km
0,268
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,524
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176219812
Reka code
1146314
4x95/50
Electric number
Size
Packaging
Voltage
4x95/50
Nominal diameter of complete cable mm
38
Nominal weight of cable kg/km
4319
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
45
In final installation, cable cm
32
During handling and installation, cable m
0.45
In final installation, cable m
0.32
Max. pulling force
Pulling-eye kN
19
Pulling-stocking kN
5.7
Resistance 20 °C Ω/km
0,193
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,387
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023325
Reka code
1146315
Nominal diameter of complete cable mm
38
Nominal weight of cable kg/km
4319
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
95
Nominal thickness of insulation mm
1.1
Number of wires
4
Min. bending radius
During handling and installation, cable cm
45
In final installation, cable cm
32
During handling and installation, cable m
0.45
In final installation, cable m
0.32
Max. pulling force
Pulling-eye kN
19
Pulling-stocking kN
5.7
Resistance 20 °C Ω/km
0,193
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,387
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023691
Reka code
1146315
4x120/70
Electric number
Size
Packaging
Voltage
4x120/70
Nominal diameter of complete cable mm
42
Nominal weight of cable kg/km
5491
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
120
Nominal thickness of insulation mm
1.2
Number of wires
4
Min. bending radius
During handling and installation, cable cm
50
In final installation, cable cm
35
During handling and installation, cable m
0.5
In final installation, cable m
0.35
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
7.2
Resistance 20 °C Ω/km
0,153
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023332
Reka code
1146316
4x150/70
Electric number
Size
Packaging
Voltage
4x150/70
Nominal diameter of complete cable mm
46
Nominal weight of cable kg/km
6626
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
150
Nominal thickness of insulation mm
1.4
Number of wires
4
Min. bending radius
During handling and installation, cable cm
55
In final installation, cable cm
38
During handling and installation, cable m
0.55
In final installation, cable m
0.38
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,124
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023714
Reka code
1146317
Nominal diameter of complete cable mm
46
Nominal weight of cable kg/km
6626
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
150
Nominal thickness of insulation mm
1.4
Number of wires
4
Min. bending radius
During handling and installation, cable cm
55
In final installation, cable cm
38
During handling and installation, cable m
0.55
In final installation, cable m
0.38
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,124
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,268
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023707
Reka code
1146317
4x185/95
Electric number
Size
Packaging
Voltage
4x185/95
Nominal diameter of complete cable mm
51
Nominal weight of cable kg/km
8366
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
185
Nominal thickness of insulation mm
1.6
Number of wires
4
Min. bending radius
During handling and installation, cable cm
61
In final installation, cable cm
43
During handling and installation, cable m
0.61
In final installation, cable m
0.43
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0991
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,193
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023356
Reka code
1146318
4x240/120
Electric number
Size
Packaging
Voltage
4x240/120
Nominal diameter of complete cable mm
57
Nominal weight of cable kg/km
10885
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
240
Nominal thickness of insulation mm
1.7
Number of wires
4
Min. bending radius
During handling and installation, cable cm
68
In final installation, cable cm
48
During handling and installation, cable m
0.68
In final installation, cable m
0.48
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0754
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,153
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6410006023363
Reka code
1146319
Nominal diameter of complete cable mm
57
Nominal weight of cable kg/km
10885
Conductor material
Copper
Nominal cross-sectional area of conductor mm2
240
Nominal thickness of insulation mm
1.7
Number of wires
4
Min. bending radius
During handling and installation, cable cm
68
In final installation, cable cm
48
During handling and installation, cable m
0.68
In final installation, cable m
0.48
Max. pulling force
Pulling-eye kN
20
Pulling-stocking kN
8.5
Resistance 20 °C Ω/km
0,0754
Maximum d.c. resistance at 20 °C, metal screen Ω/km
0,153
Minimum cable temperature during transport °C
-25
Minimum cable temperature during handling and installation °C
-15
Minimum cable temperature during operation °C
-50
Maximum conductor temperature in normal operation °C
90
Maximum conductor temperature during short circuit (not exceeding 5 sec.) °C
250
EAN code
6438176011973
Reka code
1146319